background image

36092-2-0316

Page 77

REQUIREMENTS FOR MASSACHUSETTS

For all side wall horizontally vented gas fueled equipment 

installed in every dwelling, building or structure used in whole 

or in part for residential purposes, including those owned or 

operated by the Commonwealth and where the side wall exhaust 

vent termination is less than seven feet above finished grade in 

the area of the venting, including but not limited to decks and 

porches, the following requirements shall be satisfied:

1.  INSTALLATION OF CARBON MONOXIDE DETECTORS. 

At the time of installation of the side wall horizontal vented 

gas fueled equipment, the installing plumber or gasfitter shall 

observe that a hard wired carbon monoxide detector with 

an alarm and battery back-up is installed on the floor level 

where the gas equipment is to be installed. In addition, the 

installing plumber or gasfitter shall observe that a battery 

operated or hard wired carbon monoxide detector with an 

alarm is installed on each additional level of the dwelling, 

building or structure served by the side wall horizontal 

vented gas fueled equipment. It shall be the responsibility 

of the property owner to secure the services of qualified 

licensed professionals for the installation of hard wired 

carbon monoxide detectors

 

a.  In the event that the side wall horizontally vented gas 

fueled equipment is installed in a crawl space or an attic, 

the hard wired carbon monoxide detector with alarm and 

battery back-up may be installed on the next adjacent 

floor level.

 

b.  In the event that the requirements of this subdivision 

can not be met at the time of completion of installation, 

the owner shall have a period of thirty days to comply 

with the above requirements; provided, however, that 

during said thirty day period, a battery operated carbon 

monoxide detector with an alarm shall be installed.

2.  APPROVED CARBON MONOXIDE DETECTORS. Each 

carbon monoxide detector as required in accordance with 

the above provisions shall comply with NFPA 720 and be 

ANSI/UL 2034 listed and IAS certified. 

3.  SIGNAGE. A metal or plastic identification plate shall be 

permanently mounted to the exterior of the building at 

a minimum height of eight feet above grade directly in 

line with the exhaust vent termination for the horizontally 

vented gas fueled heating appliance or equipment. The 

sign shall read, in print size no less than 1/2 inch in size, 

“GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 

OBSTRUCTIONS”.

4.  INSPECTION. The state or local gas inspector of the 

side wall horizontally vented gas fueled equipment shall 

not approve the installation unless, upon inspection, the 

inspector observes carbon monoxide detectors and signage 

installed in accordance with the provisions of 248 CMR 

5.08(2)(a) 1 through 4.

 

(b)  EXEMPTIONS: The following equipment is exempt from 

248 CMR 5.08(2)(a)1 through 4: 

 

 

1.  The equipment listed in Chapter 10 entitled 

“Equipment Not Required To Be Vented” in the 

most current edition of NFPA 54 as adopted by the 

Board; and 

 

 

2.  Product Approved side wall horizontally vented gas 

fueled equipment installed in a room or structure 

separate from the dwelling, building or structure 

used in whole or in part for residential purposes. 

 

(d)  MANUFACTURER REQUIREMENTS - GAS 

EQUIPMENT VENTING SYSTEM NOT PROVIDED. 

When the manufacturer of a Product Approved side 

wall horizontally vented gas fueled equipment does 

not provide the parts for venting the flue gases, but 

identifies “special venting systems”, the following 

requirements shall be satisfied by the manufacturer:

 

 

1.  The referenced “special venting system” 

instructions shall be included with the appliance or 

equipment installation instructions; and

 

 

2.  The “special venting systems” shall be Product 

Approved by the Board, and the instructions for 

that system shall include a parts list and detailed 

installation instruction.

 

(e)  A copy of all installation instructions for all Product 

Approved side wall horizontally vented gas fueled 

equipment, all venting instructions, all parts lists 

for venting instructions, and/or all venting design 

instructions shall remain with the appliance or 

equipment at the completion of the installation. 

Содержание DVCP36PP3 SERIES

Страница 1: ...n serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supp...

Страница 2: ...rface 2 A raised platform of combustible or non combustible material 3 If allowed by local codes A rectangular frame that contacts all four edges on the bottom of the fireplace If the fireplace is installed directly on carpeting tile or other combustible material other than wood flooring it should be installed on a metal or wood panel extending the full width and depth of the fireplace This firepl...

Страница 3: ...ardware store CARTON CONTENTS HARDWARE PACK CARTON CONTENTS DVCP36 PP SP 3 SERIES CARTON CONTENTS DVCP36 PP SP 7 SERIES Items not shown to scale INDEX NUMBER DESCRIPTION QUANTITY SUPPLIED 1 Rock Wool 1 2 Nailing Flange 5 3 Hardware Pack 1 4 Shut Off Valve 1 5 Flue Restrictor 1 6 Battery 4 7 AC Adapter 1 NS Non Combustible Board Long 2 NS Non Combustible Board Short 1 NS Installation Instructions 1...

Страница 4: ...s 37 Log Identification LSU24SPF 38 Log Placement LSU24SPF 39 46 Log Rock Identification DG30MX 47 48 Log Rock Placement DG30MX 49 56 Millivolt Standing Pilot Operating Instructions 57 58 Millivolt Standing Pilot Wiring Diagram 59 Millivolt Standing Pilot Lighting Instructions 60 Millivolt Standing Pilot Troubleshooting 61 Intermittent Pilot Electronic System Operating Instructions 62 Intermittent...

Страница 5: ...rols can be dangerous Improper installation or use of the fireplace can cause serious injury or death from fire burns explosions or carbon monoxide poisoning The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code or CSA B149 1 in Canada Available from the American National Standar...

Страница 6: ...16in 1 8in w 40ft Vertical Vent flue restrictor installed FULLY OPEN FULLY OPEN Height without standoff 39 1 2in 39 1 2in 39 1 2in 39 1 2in Width 42 1 4in 45 1 2in 42 1 4in 45 1 2in Depth 24in 24in 24in 24in Gas Inlet Shutoff Valve pipe 1 2 NPT 1 2 NPT 1 2 NPT 1 2 NPT Venting 5 x 8 See Page 26 5 x 8 See Page 26 5 x 8 See Page 26 5 x 8 See Page 26 NOTICE Air shutter settings are factory minimum set...

Страница 7: ...hed Nickel Peninsula See Thru Models Fireplace requires a log set or mixed logs and stones kit Liners are not required To add liners order two liners for See Through models One for Peninsula The following accessory parts can be obtained from your Empire Comfort Systems dealer Contact your Empire Dealer for more accessory options If you need additional information contact Empire Comfort Systems Inc...

Страница 8: ...e fireplace and center it inside the fireplace using the two holes in the floor as a visual guide See Figure 1 4 Set the rheostat control on the fireplace floor with the rheostat bracket situated as far to the right as possible See Figure 2 Figure 2 5 Snap the fan control disc into the forked prongs on the valve bracket See Figure 3 Figure 3 6 If more than one receptical is necessary in order to c...

Страница 9: ...INDEX NO PART NO DESCRIPTION QTY 1 36118 BLOWER ASSEMBLY 1 2 R7649 FAN CONTROL L120 20 1 3 R3529 CORD SET 30 INCHES 1 4 R4192 RHEOSTAT KNOB 1 5 R4186 RHEOSTAT 3 0 AMP 115 VAC 1 6 10088 RHEOSTAT BOX BRACKET 1 7 R11768 WIRE HARNESS FAN CONTROL 1 BLOWER INSTALLATION ...

Страница 10: ...om the left side of the box to the centerline of vertical vent 48 5 8 J Depth from back of box to centerline of vent 12 K Height from the bottom of the box to the gas line opening 1 3 8 L Depth from the front of the box to gas line opening 5 M Depth from rear of box to gas line opening 19 N Glass height 25 3 8 O Glass width 31 Q Distance from floor to fireplace opening 7 8 R Height from floor to v...

Страница 11: ... 45 5 8 J Depth from back of box to centerline of vent 12 K Height from the bottom of the box to the gas line opening 1 3 8 L Depth from the front of the box to gas line opening 5 M Depth from rear of box to gas line opening 19 N Glass height 25 3 8 O Glass width 31 Q Distance from floor to fireplace opening 7 8 R Height from floor to vent collar Horizontal 39 1 2 S Height from floor to vent colla...

Страница 12: ... OPENING MIN 6 TO FIREPLACE OPENING MIN 36 MIN NON COMBUSTIBLE BOARD TO 16 ABOVE FIREPLACE FACE NOTICE Dimensions apply to both See Thru and Peninsula models Figure 6 Peninsula FIREPLACE OPENING FINISHED WALL NON COMBUSTIBLE WALL COVERING COVER SEAM NON COMBUSTIBLE WALL COVERING VERTICAL FRAMING HORIZONTAL FRAMING NON COMBUSTIBLE ZONE 3 ABOVE VENT 16 NON COMBUSTIBLE BOARD HEIGHT ALL VISIBLE SIDES ...

Страница 13: ... BOARD HEIGHT ALL VISIBLE SIDES OF UNIT INDEX LETTER Y DISTANCE FROM FIREPLACE OPENING X DISTANCE FROM FINISHED WALL Dimensions in Inches A 26 12 B 24 8 C 22 6 D 20 4 1 2 E 18 2 1 4 F 16 0 Figure 9 Do not attach combustible material to the mantel of your fireplace This is a fire hazard No greeting card stockings or ornamentation of any type should be placed on or attached to the fireplace This is ...

Страница 14: ...horizontal vent length Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust certain limitations as to vent configurations apply and must be strictly adhered to See allowed vent configurations page 28 to 32 Figure 11 VENT TERMINATION CLEARANCES The horizontal vent run refers to the total length of vent pipe from the flue ...

Страница 15: ...e corner 6 in 6 in 1 In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code G Clearance inside corner 9 in 9 in 2 In Accordance with the current ANSI Z223 1 NFPA 54 National Fuel Gas Code H Clearance to each side of center line extended above meter regulator assembly 3 ft within a height 15 ft above the meter regulator assembly 3 ft A vent shall not terminate directly ...

Страница 16: ...ed Metal Tubing and Fittings ANSI Z21 45 Assembled Flexible Appliance Connectors of Other Than All Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length 2 2 SHUT OFF VALVE INCLUDED IN ENVELOPE PACK FRONT TOP 8 3 4 8 3 4 Figure 12 GAS SUPPLY PRE...

Страница 17: ...cal run of 8 feet from fireplace floor See details in Venting Section NOTICE Inuslate to applicable codes when installing this fireplace against an exterior wall A minimum clearance of 6 inches must be maintained from the perpendicular wall to the firebox opening of the fireplace if the fireplace is installed in the room divider or peninsula room divider positions LOCATING FIREPLACE ...

Страница 18: ...installation of the fireplace can cause serious injury or death from fire burns explosions or carbon monoxide poisoning A factory installed junction box is located on the outside wall of the fireplace on the vent side Wiring must be fed to the junction box and attached to the stranded wire inside with wire nuts Connect white to white black to black and ground green stranded wire to the ground scre...

Страница 19: ... material The fireplace framing should be constructed of 2 x 4 lumber The framing members may rest on the fireplace standoffs however the stand offs are not load bearing Refer to Figures 17 and 18 for minimum framing dimensions You may install a see through fireplace in a load bearing wall however the wall s framing must include a structural header above the fireplace designed to support all of th...

Страница 20: ... 9 on page 13 for maximum mantel depth and minimum height above fireplace Figure 19 Clearance to Combustibles Back 0in Sides Near Face See Figure 20 0in Floor 0in Top Stand off 0in Outer Top to Framing 3in Above Vent 3in FINISHED WALL NON COMBUSTIBLE WALL COVERING VERTICAL FRAMING NOTE ORIENTATION OF STUD AGAINST THE FIREPLACE 20 FRAMING ON FLOOR NON COMBUSTIBLE ZONE NON COMBUSTIBLE ZONE LEAVE SPA...

Страница 21: ...stment of the nailing flange position can be made by using either the outer or inner pair of holes OFFSET 5 8 OFFSET Figure 22 3 If necessary the positions of the side nailing flanges can adjusted by loosening but do not remove the top and bottom screws anchoring the bracket in place using a center screw from the hardware pack and re tightening the top and bottom screws See Figure 23 1 2 POSITION ...

Страница 22: ...arance to combustibles above the vent pipe See Figure 27 Figure 27 45 ELBOW WITH HORIZONTAL TERMINATION VENT CAP WALL THIMBLE 3 MININUM CLEARANCE TO COMBUSTIBLES IN WALL 46 13 16 TO COMBUSTIBLES ABOVE VENT INSIDE WALL Figure 28 45 ELBOW A VENT CAP WALL FIRESTOP THIMBLE B MINIMUM PIPE LENGTH A FIREPLACE TO EXTERIOR WALL B Dimensions in inches 9 10 5 8 12 13 5 8 18 19 5 8 24 25 5 8 MAXIMUM REAR VENT...

Страница 23: ...T OUT MINIMUM A2 B C C B E D DIMENSIONS in inches A1 49 5 8 B 5 5 16 C 7 5 16 D 10 5 8 E See top vent configuration charts for allowable A2 and E dimensions pages 28 and 29 A2 MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL INSTALLATIONS WITH 90 DEGREE ELBOW SEE FIGURE 41 ON PAGE 27 FOR PERMISSIBLE TOP VENT HORIZONTAL AND VERTICAL DIMENSIONS Figure 30 Installing Support Brackets Install a ho...

Страница 24: ...tem which pass through ceilings require the use of ONE ceiling firestop at the hole in each ceiling through which the vent passes Position a plumb bob directly over the center of the vertical vent component and mark the ceiling to establish the center point of the vent Drill a hole or drive a nail through this center point and check the floor above for any obstructions such as wiring or plumbing r...

Страница 25: ...e and proper drainage to be installed around the termination area 3 7 6cm MINIMUM PIPE STRAP 48 122cm COMBUSTIBLE PROJECTION 18 45 7cm MINIMUM 12 30 5cm ABOVE GRADE OR AVERAGE SNOWFALL TYPICAL BASEMENT INSTALLATION Figure 39 NOTICE For proper flame appearance use flue restrictor for vertically terminated fireplaces Do not use for horizontally terminated fireplaces Figures 36 to 38 show the locatio...

Страница 26: ...ceptable Check all clearances and venting components Identify problems existing in the vent system if any Use pages 27 to 34 for venting to eliminate issues after installation Check pipe diameter on vent system and fireplace to verify the size is the same NOTICE All outer connection joints must be sealed with aluminum tape screws or silicone sealant rated above 300 F 149 C The inner flue joints do...

Страница 27: ...e reduced by 18 inches Reduce 3 feet for every 90 elbow This does not apply if the 45 elbows are installed on the vertical part of the vent system Example According to the chart the maximum horizontal vent length is 20 feet and if two 45 elbows are required in the horizontal vent it must be reduced to 17 feet The maximum number of 45 elbows permitted per side wall installation is two These elbows ...

Страница 28: ...t 8ft 12ft 17ft 8in 20ft 24ft 10ft Figure 43 Two Elbows NOTICE Subtract 3 feet from the total horizontal measurement for each 90 elbow installed horizontally Subtract 1 1 2 feet from the total horizontal measurement for each 45 elbow installed horizontally INSTALLED HORIZONTALLY B A TO BOTTOM OF UNIT INSTALLED VERTICALLY EXAMPLE VENT RUNS INITIAL PIPE LENGTH A Vertical B Horizontal Maximum 36in 6f...

Страница 29: ... the total horizontal measurement for each 45 elbow installed horizontally A TO BOTTOM OF UNIT B INSTALLED VERTICALLY EXAMPLE VENT RUNS INITIAL PIPE LENGTH A Vertical B Horizontal Maximum 36in 6ft 7ft 4in 48in 7ft 12ft 8ft 12ft 14ft 8in 21ft 25ft 7ft Figure 47 Two Elbows A TO BOTTOM OF UNIT B INSTALLED VERTICALLY EXAMPLE VENT RUNS A Vertical B Horizontal Maximum 6ft 10ft 4in 7ft 15ft 12ft 17ft 8in...

Страница 30: ...ust be increased In high wind conditions nearby trees adjoining roof lines steep pitched roofs and other similar factors can result in poor draft or down drafting In these cases increasing the vent height may solve this problem General Maintenance Inspect venting system semi annually as follows 1 Check for corrosion areas of the venting system exposed to the elements These will appear as rust spot...

Страница 31: ...teps Improper installation of the fireplace can cause serious injury or death from fire burns explosions or carbon monoxide poisoning NOTICE Build the chase large enough to accommodate the minimum clearance of combustible materials including insulation to the vent system When installing the vent system in a chase insulate the chase as you would the outside walls of your home This is especially imp...

Страница 32: ...cal installations up to 40 feet in height b Two sets of 45 elbow offsets within these vertical installations A vent pipe from 0 to a maximum of 8 feet can be used between elbows c Wall straps must be used to support offset pipe every 4 feet This application will require that you first determine the roof pitch and use the appropriate venting components OFFSET CHART RISE OFFSET SIZE 5in X 8in ELBOW ...

Страница 33: ... Figure 55 DVVK 5F FLEX VENT INSTRUCTIONS 5 FLEX VENT PIPE SPACER SPRING 8 FLEX VENT PIPE Figure 56 3 Attach a 6in piece of hard pipe to raise the connection point above the fireplace 4 Use existing 8in diameter inlet collar to attach outer vent pipe 5 Install the Wall Firestop Thimble assembly as required through the wall Refer to the venting charts in the fireplace manual to determine the proper...

Страница 34: ...nsert the adapter into the 45 elbow s inner flue pipe Secure flue adapter with a minimum of two screws provided See Figure 57 11 Attach the Outer Vent pipe to the 45 elbow with a large band clamp provided Sealant may also be used on the outer vent connections 12 Check all vent connections for tightness Make sure horizontal venting has the proper rise and combustible clearances required Refer to ve...

Страница 35: ...l and corresponding maximum horizontal dimensions of mantels or other combustible projections above the top front edge of the fireplace Only non combustible materials may be used to cover the black fireplace front WARNING When finishing the fireplace never obstruct or modify the air inlet outlet louvers in any manner Provide adequate clearances around air openings into the combustion chamber CAUTI...

Страница 36: ...way from the fireplace See Figure 60 Figure 60 3 Set the brick bracket against the firebox wall as shown in Figure 61 Figure 61 4 Screw the brick bracket to the false floor but do not tighten with the screws shown on the left side of Figure 62 Vent Pilot side liner only 5 Use the self drilling screws shown on the right side of Figure 62 to attach the brick bracket to the firebox wall 2 1 Figure 62...

Страница 37: ...s shown below NOTICE Pieces of glowing embers should be fluffed up prior to placement onto the burner Replacement of loose material glowing embers must be purchased from an Empire Comfort Systems Dealer Application of excess loose material glowing embers may adversely affect performance of the fireplace A single layer of embers is to be used when applying Platinum Bright Embers in combination with...

Страница 38: ... is very important that part number and description coincide Log Description Part Number Front View Top View Log A 36018 Log B 36019 Log C 36027 Log D 36025 Log E 36021 Log F 36023 Log G 36020 Log H 36028 Log I 36022 Log J 36026 Log K 36024 36092 2 0316 Page 38 ...

Страница 39: ...ge 38 Log Identification to order logs for your appropriate model number NOTICE Once the installation is complete with the glowing embers and log set in place operate the fireplace to verify flame appearance If there are flames directly impinging a log turn off fireplace then remove the glowing ember material directly below where the flame impingement occurred This should eliminate sooting on the ...

Страница 40: ...LOG PLACEMENT LSU24SPF 1 Place Log H on to burner tabs 6 and 2 Place Log J onto burner tab 3 Refer to the images on this page 36092 2 0316 Page 40 ...

Страница 41: ...LOG PLACEMENT LSU24SPF 2 Place Log A on to burner pins 7 8 9 10 and 11 Refer to the images on this page 36092 2 0316 Page 41 ...

Страница 42: ...LOG PLACEMENT LSU24SPF 3 Place Log E onto burner tab 4 and the pin on Log A Refer to the images on this page 36092 2 0316 Page 42 ...

Страница 43: ...LOG PLACEMENT LSU24SPF 4 Place Log I onto burner tab 1 and the left pin on Log E Place Log F onto burner tab 5 and the right pin on Log E Refer to the images on this page 36092 2 0316 Page 43 ...

Страница 44: ...LOG PLACEMENT LSU24SPF 5 Place Log B onto burner tab 13 and left pin on Log A Place Log C onto burner tab 14 Place Log K onto burner tabs 12 and 16 Refer to the images on this page 36092 2 0316 Page 44 ...

Страница 45: ...LOG PLACEMENT LSU24SPF 36092 2 0316 Page 45 ...

Страница 46: ...ment is complete Refer to the images on this page A bag of wood splinters and vermiculite is included with your log set and may be arranged on the false floor to suit your preference Do not place them on the burner 36092 2 0316 Page 46 ...

Страница 47: ...p View Stone A 36031 Stone B 36030 Stone C 36029 Stone D 36032 Stone E 36033 Stone F 36037 Stone G 36034 Stone H 36035 Stone I 36036 Log J 36039 Log K 36044 Attention When ordering parts it is very important that part number and description coincide 36092 2 0316 Page 47 ...

Страница 48: ... DG30MX Log L 36040 Log M 36042 Log N 36038 Log O 36043 Log P 36041 Description Part Number Front View Top View Attention When ordering parts it is very important that part number and description coincide 36092 2 0316 Page 48 ...

Страница 49: ...age 47 48 Log and Rock Identification to order logs for your appropriate model number NOTICE Once the installation is complete with the glowing embers and log set in place operate the fireplace to verify flame appearance If there are flames directly impinging a log turn off fireplace then remove the glowing ember material directly below where the flame impingement occurred This should eliminate so...

Страница 50: ...LOG STONE PLACEMENT DG30MX 1 Place Stone F onto burner tab 1 Place Stone G onto burner tab 5 Place Stone I onto the false floor as shown below Refer to the images on this page 36092 2 0316 Page 50 ...

Страница 51: ...TONE PLACEMENT DG30MX 2 Place Stone A onto burner pins 7 and 8 Place Stone B onto burner pins 9 and 10 Place stone C onto burner pin 11 and burner tab 12 Refer to the images on this page 36092 2 0316 Page 51 ...

Страница 52: ...LOG STONE PLACEMENT DG30MX 3 Place Stone E onto burner tab 13 Place Stone D onto burner tab 16 Place Stone H onto the false floor as shown below Refer to the images on this page 36092 2 0316 Page 52 ...

Страница 53: ...LOG STONE PLACEMENT DG30MX 4 Place Log P onto burner tab 2 and center pin on Stone B Place Log L onto burner tab 4 and pin on Stone G Refer to the images on this page 36092 2 0316 Page 53 ...

Страница 54: ...LOG STONE PLACEMENT DG30MX 5 Place Log O onto burner tab 14 and left pin on Stone B Place Log N onto burner tab 3 and right pin on Stone B Refer to the images on this page 36092 2 0316 Page 54 ...

Страница 55: ...MENT DG30MX 6 Place Log J onto burner tab 6 and pin on Stone E Place Log K onto burner tab 15 and pin and Stone C Place Log M onto burner tab 17 and pin on Stone D Refer to the images on this page 36092 2 0316 Page 55 ...

Страница 56: ...ent is complete Refer to the images on this page A bag of wood splinters and vermiculite is included with your mixed logs and stone set and may be arranged on the false floor to suit your preference Do not place them on the burner 36092 2 0316 Page 56 ...

Страница 57: ... the PILOT position to the ON position This allows the millivolts current to build up to a sufficient level to operate the gas control properly 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found in control compartment behind the door assembly CAUTION During the initial purging and subsequent lightings never allow the gas valve control...

Страница 58: ... NOTICE If batteries fail in the remote and immediate heat is desired turn the REMOTE OFF ON switch from the REMOTE position to the ON position Installation of Remote Receiver Place remote receiver on the floor of fireplace behind the louver as far forward as possible Attention The Velcro loop and hook are not necessary in this installation but can be used to secure remote receiver Refer to remote...

Страница 59: ... into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug PILOT THERMOCOUPLE REAR CONNECTION GAS VALVE THERMOPILE REMOTE OFF ON REMOTE OFF ON SWITCH INCLUDED OPTIONAL REMOTE CONTROL RECEIVER OPTIONAL WALL SWITCH OPTIONAL THERMOSTAT CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous ope...

Страница 60: ...tch to desired setting 1 Set REMOTE OFF ON switch to OFF 2 Turn off all electric power to the appliance if service is to be performed if applicable 3 Lift off bottom access panel 4 Push in gas control knob slightly and turn clockwise to OFF Do not force 5 Replace bottom access panel MILLIVOLT STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS TO TURN OF...

Страница 61: ... connections from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Clean thermopile Check the thermopile with a millivolt meter Take the reading at TH TP TP terminals of the gas valve The meter should read 350 millivolts minimum while holding the valve knob depressed in the PILOT position with the pilot lit and the REMOTE OFF ON switch...

Страница 62: ...utage periods it is recommended that the pilot remain in the CPI standing pilot mode to reduce cold start issues and or conserve battery backup power during a power outage 3 The gas valve has inlet and outlet pressure taps as shown in Figure 75 Refer to page 16 for gas pressure requirements NOTICE The gas control has a manual HI LO flame adjustment knob regulator that allows you to increase or dec...

Страница 63: ...eceptacle Do not cut or remove the grounding prong from this plug CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation CAUTION Do not operate the fireplace with glass panel removed cracked or broken Replacement of the panel should be done by a licensed or qualified service person WARNING Improper installation adjustment alt...

Страница 64: ...YOUR SAFETY READ BEFORE LIGHTING INTERMITTENT PILOT LIGHTING INSTRUCTIONS A This appliance has a pilot which can be lighted with the manual on off switch a remote control or by switching the receiver switch to the ON position When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is...

Страница 65: ...T PILOT CONTROL SYSTEM TROUBLESHOOTING Troubleshooting Before proceeding with the procedures in the following troubleshooting table verify that the power supply AC DC adapter is present and that the batteries inside the receiver and or optional battery pack are fresh and installed with correct polarity Make sure all the connections between the wire harnesses and system components are proper and po...

Страница 66: ...36092 2 0316 Page 66 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING ...

Страница 67: ...36092 2 0316 Page 67 INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING ...

Страница 68: ...removed to service an fireplace must be replaced prior to operating the fireplace Check Vent System The fireplace and venting system should be inspected before initial use and at least annually by a qualified service person Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air flow Glass Cleaning WARNING Do not use Ammonia based or abrasive cleane...

Страница 69: ...ntremoved cracked or broken Replacement of the glass should be done by a licensed or qualified service person Figure 76 Separating Screen Frame From Glass Frame 1 Turn glass and screen frame assembly upside down and rest the glass frame on a block of wood step or similar object 2 Push downwards on screen frame to release the tabs from the glass frame Note When reattaching screen frame to glass fra...

Страница 70: ...failure to use only parts specifically approved with this appliance may result in property damage or personal injury BURNER ASSEMBLY IP VALVE 30 29 28 34 33 31 20 21 32 24 23 22 19 MILLIVOLT VALVE 20 21 24 23 22 19 26 25 27 38 39 40 45 44 43 42 41 37 36 37 35 6 5 4 1 1 18 17 16 15 14 8 8 6 5 4 10 9 9 8 8 38 2 2 7 46 ...

Страница 71: ...R10882 ELBOW 3 8 NPT X 3 8 FLARE 25 R9760 R9760 PIEZO IGNITOR 26 R3436 R3436 SWITCH 27 36045 36045 PIEZO AND SWITCH BRACKET 28 R11127 R11127 CONTROL BOARD MODULE 29 29382 29382 MODULE TRAY 30 R11122 R11122 BATTERY HOLDER 31 R2566 R2566 WIRE ASSEMBLY ORANGE BLACK 32 R11128 R11128 AC ADAPTER 33 R2522 R2522 SWITCH ON OFF 34 R11123 R11123 PROFLAME WIRE HARNESS 35 35281 35281 FALSE FLOOR STONES 35 3605...

Страница 72: ... to use only parts specifically approved with this appliance may result in property damage or personal injury BURNER ASSEMBLY IP VALVE 30 29 28 34 33 31 20 21 32 24 23 22 19 MILLIVOLT VALVE 20 21 24 23 22 19 26 25 27 38 39 40 45 44 42 41 37 36 37 35 6 5 4 1 1 18 17 16 15 14 8 8 6 5 4 10 9 9 8 8 38 2 2 13 11 12 7 2 3 46 43 43 ...

Страница 73: ...AIGHT 23 R7577 R7578 VALVE MV 23 R11125 R11126 VALVE IP 24 R10882 R10882 ELBOW 3 8 NPT X 3 8 FLARE 25 R9760 R9760 PIEZO IGNITOR 26 R3436 R3436 SWITCH 27 36045 36045 PIEZO AND SWITCH BRACKET 28 R11127 R11127 CONTROL BOARD MODULE 29 29382 29382 MODULE TRAY 30 R11122 R11122 BATTERY HOLDER 31 R2566 R2566 WIRE ASSEMBLY ORANGE BLACK 32 R11128 R11128 AC ADAPTER 33 R2522 R2522 SWITCH ON OFF 34 R11123 R111...

Страница 74: ... can be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following illustration and part list Be sure to ...

Страница 75: ...or servicing the fireplace must be replaced prior to operating the fireplace Work should be done by a qualified service person A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this fireplace and shall be installed for the protection of children and other at risk individuals Any safety screen guard or barrier removed to service a fireplace must be replaced ...

Страница 76: ...caped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in a closed area and the odor intensity could vary at different levels Since it is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you detect any...

Страница 77: ...sions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight feet above grade directly in line with the exhaust vent termination for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less th...

Страница 78: ...36092 2 0316 Page 78 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes ...

Страница 79: ...nted parts to and from the factory Claims that do not involve defective workmanship or materials Unauthorized service or parts replacements Removal and reinstallation cost Inoperable due to improper or lack of maintenance How To Get Service To make a claim under this warranty please have your receipt available and contact your installing dealer Provide the dealer with the model number serial numbe...

Страница 80: ...rt Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Отзывы: