Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system.
Determine how the vent system will be terminated out the
side of the house or through the roof. Verify clearances for the
termination.
When selecting a vent system for use with the fireplace, refer
to the “Venting Fireplace” section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify problems existing in the vent system, if
any. Use pages 27 to 34 for venting to eliminate issues after
installation. Check pipe diameter on vent system and fireplace to
verify the size is the same.
NOTICE: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
Figure 40
Use one of the following 5 x 8 vent systems:
Simpson Duravent® GS
American Metal Products
Selkirk Direct-Temp®
ICC
Security Secure Vent
Simpson Duravent - DVA-H2
Empire Flex Vent Kit - DVVK-5F
TOP VENT SYSTEM IDENTIFICATION
VENTING FIREPLACE - TOP
VENT SYSTEMS