![Empire Comfort Systems BFR2124RN Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/empire-comfort-systems/bfr2124rn/bfr2124rn_installation-instructions-and-owners-manual_2403831018.webp)
39246-0-0718
Page 18
NOTICE:
Thermostats are not approved on vented decorative
appliances.
Label all wires prior to disconnection when servicing controls. Wiring
errors can cause improper and dangerous operation. Verify proper
operation after servicing.
The gas valve does not require 24 or 110 volts. See pages 19 - 21
for remote control instructions.
It is important to use wire of a proper gauge for the length of the wire:
RECOMMENDED WIRE GAUGES
Maximum Length
Wire Gauge
1' to 10'
18
10' to 25'
16
25' to 35'
14
HI / LOW (BFR) WIRING
Remote Receiver
Use the following steps to place the
remote receiver
adjacent to
the gas valve.
Attention:
1. The remote receiver cannot be placed behind the gas valve and
burner assembly.
2. When facing the appliance, the remote receiver must be placed
in the
right
side firebox, toward the front.
NOTICE
:
Do not let remote control receiver come in contact with
burner assembly.
Refer to remote control installation and operating instructions for
more details on remote control.
Wiring Diagram
Figure 13