background image

35646-2-0617

Page 7

Introduction

Always consult your local Building Department regarding regula-

tions, codes or ordinances which apply to the installation of a 

vented decorative gas log set in a solid-fuel burning fireplace.

This appliance is only for use with the type of gas indicated on 

the rating plate.

Instructions to Installer

1.   Installer must leave instruction manual with owner after 

installation.

2.   Installer must have owner fill out and mail warranty card 

supplied with the fireplace.

3.   Installer should show owner how to start and operate the 

fireplace.

WARNING

ANY CHANGE TO THIS APPLIANCE OR ITS CONTROLS 

CAN  BE  DANGEROUS. 

Improper installation or use of 

the appliance can cause serious injury or death from fire, 

burns, explosion or carbon monoxide poisoning.

INTRODUCTION

General Information
Any alteration of the original design, installed other than as 

shown in these instructions or use with a type of gas not 

shown on the rating plate is the responsibility of the person 

and company making the change.

Important

All correspondence should refer to complete Model No., Serial 

No. and type of gas.

NOTICE: 

During initial use of the ceramic logs and branches you 

will detect an odor as the ceramic logs and branches are cured.

You must secure the gas burner to the fireplace floor. If not, the 

entire unit may move when you adjust the controls. Movement 

of unit may cause shifting of the gas logs which leads to sooting 

and improper burning. Grate movement could cause a gas leak.
Special care is required if you are installing the unit into a 

sunken fireplace. You must raise the fireplace floor to allow 

access to gas log controls. This will insure adequate air flow 

and  guard  against  sooting.  Raise  the  fireplace  floor  using 

noncombustible materials.

Assembly Procedure: 

1.  Center the gas log unit in the fireplace or firebox. Make  

certain the front feet of the grate sit inside the front edge of the 

fireplace or firebox.

2.  An anchor hole is provided in the two bottom side members of 

the grate frame. After centering the grate correctly, mark the 

hole positions on the fireplace/firebox floor. Drill two (2) 5/32" 

diameter holes approximately 1-1/2" deep for masonry screws 

or 1/8" hole for sheet metal screws.

3.  Anchor the grate to the fireplace/firebox floor using the screws 

provided. Refer to 

Figure 13. 

Proper installation of the grate is essential to prevent any  

movement of the gas logs and controls during operation.

Figure 13

BEFORE FULLY INSTALLING THE APPLIANCE

Содержание AVL21MTEKN-1

Страница 1: ...any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call...

Страница 2: ...Introduction 7 Before Fully Installing the Appliance 7 Product Specifications 8 Gas Supply 9 Installation 10 12 Final Set Up 13 Operation 14 Maintenance Service 14 Cleaning Servicing 14 Appliance Serv...

Страница 3: ...on Fitting 1 1 5 Ember Burner Pan 1 1 6 Ember Burner 1 1 7 Dampler Clamp 1 1 8 Flexline 1 1 9 Street Elbow 1 2 X 3 8 1 1 10 Rockwool Mix 1 1 12 Decorative Rock 3 3 13 Crushed Glass 1 2 See Parts Lists...

Страница 4: ...liance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or c...

Страница 5: ...may produce annoying smoke and smells as they are burned off during the initial operation of the appliance This may possibly cause headaches and eye or lung irritation This is a normal and temporary...

Страница 6: ...ove sea level However if the heating value of the gas has been reduced this general rule may not apply Check with local gas utility for proper orifice size identification For Canadian high altitude ap...

Страница 7: ...of the ceramic logs and branches you will detect an odor as the ceramic logs and branches are cured You must secure the gas burner to the fireplace floor If not the entire unit may move when you adjus...

Страница 8: ...allows for centering the log set When adding valve kit to a Triple Burner add 6 inches to minimum fireplace width shown above PRODUCT SPECIFICATIONS MINIMUM FIREPLACE DIMENSIONS MASONRY BUILT FIREPLAC...

Страница 9: ...nd foreign particles may collect The use of the following gas connectors is recommended ANS Z21 24Appliance Connectors of Corrugated MetalTubing and Fittings ANSZ21 45AssembledFlexibleApplianceConnect...

Страница 10: ...excess of 1 2 PSI 3 5 KPA Use a system manual shut off valve to shut off the gas supply to this gas appliance before continuing with installation procedures WARNING When installing the appliance DO NO...

Страница 11: ...her a wire brush or steel wool Apply Teflon tape or pipe dope to the steel fittings before making any connection Notice All gas connections except for brass to brass require Teflon tape or pipe dope F...

Страница 12: ...mber burner See Figure 12 3 Push the ember burner pan backwards towards the main burner snapping the top of the ember burner pan beneath the grate support See Figure 13 FOR MATCH THROW INSTALLATIONS G...

Страница 13: ...material not sup plied with this appliance All previously applied loose mate rial embers must be removed prior to reapplication CAUTION DO NOT place glowing embers sand rockwool mix or lava rock cinde...

Страница 14: ...of the following options A While the logs are burning and hot spray the logs with clean water The soot will lift off and burn off B When the logs are cold brush the soot off with a stiff brush Do not...

Страница 15: ...35646 2 0617 Page 15 Date Dealer Name Service Technician Name Service Performed Notes APPLIANCE SERVICE HISTORY...

Страница 16: ...essure Check gas supply pressure Faulty valve Replace valve Faulty pilot or thermocouple Replace Safety pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will not stay on L...

Страница 17: ...R12047 R12047 R12224 Orifice 5 R12055 R12055 R12055 Orifice Holder 6 R12083 R12083 R12083 Flexline 7 R12162 R12163 R12164 Ember Burner Pan 8 R12116 R12116 R12116 Compression Fitting 9 R12157 R12158 R1...

Страница 18: ...fires and all causes beyond our control HOW TO ORDER REPAIR PARTS To Order Parts Under Warranty please contact your local Empire dealer See the dealer locator at www empirecomfort com To provide warra...

Страница 19: ...ion Duties of the Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the appliance A bill of sale cancelled check or payment...

Страница 20: ...mfort com Empire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact...

Отзывы: