![Emotron VSA 23-01 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/emotron/vsa-23-01/vsa-23-01_quick-setup-manual_2403277038.webp)
Emotron AB 01-3991-11r2
Introduction
37
Step 2 Apply power to the drive
Apply AC power to the drive and observe operator. Three 7-segment display
should show power voltage for 3 to 5 seconds and observe how it runs, factory
sets 5.00. (Frequency Command of 7-segment display should be flashed all the
time.)
Step 3 Check motor rotation without load
•
Press the
key. The 7-segment display will indicate the output frequency
00.0 to 05.0 Hz.
•
Check the operation direction of the motor. If the direction is not correct:
Press the
key and turn off the AC power supply. After power indicator
LED is off, switch T1 and T2.
•
Apply power again and press the
key and check the motor operation
direction.
Step 4 Check full speed at 50Hz/60Hz
•
Change the frequency with the
or
key and please press the
key to confirm the setting.
•
Set the frequency to 50/60 Hz according to the above regulations.
•
Press the
key and inspect the motor operation as motor accelerates to
full speed.
•
Press the
key and inspect the motor operation as motor decelerates.