background image

 

 

Instruction elliptical trainer 900 / 900 med

 

Version 1.1 07.06.2022

 

Page 8 from 13 

 

Pulse systems 

All  devices  of  the motion cardio line  900 and  motion  cardio line 900 med  have  an  original

 pulse system in 

which the signal  acquisition is carried out  by means  of a chest strap as standard (the chest strap  transmitter is not 
included  in  the  scope  of  delivery).  Wireless  data  transmission  to  the  display  electronics  is  via  a  coded  5  kHz  or

 connection. The

 technology is based on signal transmission through a magnetic field. This magnetic 

field can be disturbed by many factors. The most common causes are the use of incompatible chest straps, some of 
which have much greater ranges. Loudspeakers, TVs, power cables, fluorescent tubes and high-powered motors can 
also interfere. For the most interference-free transmission of the heart rate, we recommend the use of original

 

sensors, such as the H10 sensor. The pulse rate measurement is then ECG accurate.  
 

 
 

 

Inductive charging (optional) 

An optional inductive charging module can be activated on all motion cardio line 900 and motion cardio line 900 med 
units via the "connect package". This allows mobile devices that comply with the Qi standard (

 ) to be 

charged 

without contact. Wearers of pacemakers or implanted defibrillators (ICDs) are recommended to keep a minimum 
distance of 10 cm from the charging coil. 

 

5.  Care, maintenance and servicing 

All cardio equipment from emotion fitness is durable and requires little maintenance to function as training equipment 
for a long time. However, it is imperative that the necessary care is carried out conscientiously. 

 

 Warning: 

The unit must only be opened by an authorised specialist 

 

Symbols and meaning 
 
Safety sign 

Reference 

Title 

 

ISO 7010-P017 

Pushing prohibited 

 

ISO 7010-W012 

Warning, Electricity 

 

ISO 7000-1641 

Instructions for use 

 

DIN EN ISO 20957 

Safety Notice Heart Rate 
Monitoring 

 

ISO 7000-3082 
 

Manufacturer 

Safety instruction according to DIN EN ISO 

20957 

Warning. Heart rate monitoring systems can be  inaccurate. Excessive 
exercise can cause serious damage to health or death. Stop exercising 
immediately if you feel dizzy or weak. 

Содержание motion cross 900

Страница 1: ...Instruction elliptical trainer 900 900 med Version 1 1 07 06 2022 Page 1 from 13 Instructions for use for motion cross 900 motion cross 900 med...

Страница 2: ...ning 5 Indications and contraindications 6 4 Operating the display 7 Overview display key functions 7 Pulse systems 8 Inductive charging optional 8 5 Care maintenance and servicing 8 Instructions for...

Страница 3: ...n the joints affected during training The equipment enables reproducible physical loading of the human body and the cardiovascular system for the purposes of prevention rehabilitation and diagnosis Te...

Страница 4: ...stallation of the equipment Fig 1 Side view of the unit with designation of the essential elements Adjustable feet for levelling Pedals Position name plate Rigid hand grips for support during lower li...

Страница 5: ...n training tight fitting lightweight sports clothing is preferable so that it cannot get caught in parts of the device during training Always wear suitable sports shoes for a secure footing on the ped...

Страница 6: ...o disconnect it e g by means of floor tanks installation under the unit or cable ducts position of the power supply in areas that are difficult to access Warning If the medical device is modified appr...

Страница 7: ...se the key or key to increase or decrease the parameters or power values to be set Use the arrow keys to navigate through the corresponding menus and confirm values or settings Swipe swipe gestures na...

Страница 8: ...arging optional An optional inductive charging module can be activated on all motion cardio line 900 and motion cardio line 900 med units via the connect package This allows mobile devices that comply...

Страница 9: ...imitation ISO 7010 W001 General warning sign ISO 7010 M002 Follow the operating instructions IEC 60417 5840 Type B applied part concerns saddle pedals and handlebars The safety level of the units can...

Страница 10: ...rom the PC after the specified time period Restart the PC and plug the USB dongle into the PC again If necessary restart the software service All ergometers Radio Problem verbos The unit does not rece...

Страница 11: ...h a damp cloth and mild soap then wipe dry again The use of spray bottles with cleaning agents is not permitted it has been shown that the units never become dry in inaccessible places Rust infestatio...

Страница 12: ...and regulations at the location of the units Your local authorised dealer can also provide further information 6 Technical data Device type Dimensions L W H Weight Max user weight Safe workload motion...

Страница 13: ...e of service The following procedures are conceivable 1 the service is carried out on site by our service 2 we send the desired spare part 3 we will send a replacement unit The defective parts shall b...

Отзывы: