background image

 

 

Instruction elliptical trainer 900 / 900 med

 

Version 1.1 07.06.2022

 

Page 4 from 13 

 

3.  Safety instructions  

Safe installation of the equipment  

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig.1: Side view of the unit with designation of the essential elements

 

 
 
 
 
 
 

 

Adjustable feet for 
levelling  

Pedals  

Position name 
plate  

Rigid hand grips for support during 
lower limb exercises 

Display for showing training data and 
setting the gear 

Movable handles for the 
whole body workout 

Содержание motion cross 900

Страница 1: ...Instruction elliptical trainer 900 900 med Version 1 1 07 06 2022 Page 1 from 13 Instructions for use for motion cross 900 motion cross 900 med...

Страница 2: ...ning 5 Indications and contraindications 6 4 Operating the display 7 Overview display key functions 7 Pulse systems 8 Inductive charging optional 8 5 Care maintenance and servicing 8 Instructions for...

Страница 3: ...n the joints affected during training The equipment enables reproducible physical loading of the human body and the cardiovascular system for the purposes of prevention rehabilitation and diagnosis Te...

Страница 4: ...stallation of the equipment Fig 1 Side view of the unit with designation of the essential elements Adjustable feet for levelling Pedals Position name plate Rigid hand grips for support during lower li...

Страница 5: ...n training tight fitting lightweight sports clothing is preferable so that it cannot get caught in parts of the device during training Always wear suitable sports shoes for a secure footing on the ped...

Страница 6: ...o disconnect it e g by means of floor tanks installation under the unit or cable ducts position of the power supply in areas that are difficult to access Warning If the medical device is modified appr...

Страница 7: ...se the key or key to increase or decrease the parameters or power values to be set Use the arrow keys to navigate through the corresponding menus and confirm values or settings Swipe swipe gestures na...

Страница 8: ...arging optional An optional inductive charging module can be activated on all motion cardio line 900 and motion cardio line 900 med units via the connect package This allows mobile devices that comply...

Страница 9: ...imitation ISO 7010 W001 General warning sign ISO 7010 M002 Follow the operating instructions IEC 60417 5840 Type B applied part concerns saddle pedals and handlebars The safety level of the units can...

Страница 10: ...rom the PC after the specified time period Restart the PC and plug the USB dongle into the PC again If necessary restart the software service All ergometers Radio Problem verbos The unit does not rece...

Страница 11: ...h a damp cloth and mild soap then wipe dry again The use of spray bottles with cleaning agents is not permitted it has been shown that the units never become dry in inaccessible places Rust infestatio...

Страница 12: ...and regulations at the location of the units Your local authorised dealer can also provide further information 6 Technical data Device type Dimensions L W H Weight Max user weight Safe workload motion...

Страница 13: ...e of service The following procedures are conceivable 1 the service is carried out on site by our service 2 we send the desired spare part 3 we will send a replacement unit The defective parts shall b...

Отзывы: