6
Wiring Diagram | Example of Most Common Connection for Lock
Control
(see Fig. 3, 4)
Conductor Description
1 – Red
12 V + power supply
2 – Black
12 V – power supply
3 – Brown
Door contact
4 – Orange
Exit button 1 (activates relay contact without code)
5 – Yellow
Exit button 2 (activates relay contact without code)
6 – Blue
Relay 2 contact – NO (normally-open)
7 – Purple
Relay 2 contact – COM
8 – Grey
Relay 2 contact – NC (normally-closed)
9 – White
Relay 1 contact – NO (normally-open)
10 – Pink
Relay 1 contact – COM
11 – Turquoise
Relay 1 contact – NC (normally-closed)
12 – Green
GND
Do not dispose with domestic waste. Use special collection points for sorted waste.
Contact local authorities for information about collection points. If the electronic
devices would be disposed in landfill, dangerous substances may reach ground-
water and subsequently food chain, where it could affect human health.
Emos spol s.r.o. declares that the H8010/H8011 is in compliance with the essential
requirements and other relevant provisions of Directive.
The device can be freely operated in the EU.
The Declaration of Conformity can be found at
http://www.emos.eu/download.
CZ | Vstupní kódová klávesnice
Popis:
(viz obr. 1)
1 – Indikátor sepnutí relé
2 – Indikátor stavu
3 – Klávesnice
4 – Připevňovací šroub
Instalace:
(viz obr. 2)
Popis funkcí:
Zóna 1: (Relé 1 – primární)
– Slouží pouze k ovládání spínacího relé.
– Adresy 000–999 (1 000 kódů).
Zóna 2: (Relé 2 – sekundární)
– Slouží k ovládání 2. spínacího relé, nebo jako tlačítko zvonku k zazvonění (přepí-
natelná funkce).
– Adresy 00–09 (10 kódů).