2
3
Rechargeable LED flashlight with focus, E-1102
GB
Universal rechargeable flashlight with accumulator,
resistant to rough conditions (dust, dirt). The flashlight
body is made of an aluminium alloy. 5 W LED ensures
sufficiently high luminous intensity. Perfect for outdoors-
men, gamekeepers, and for working environments – for
geologists, miners, fire-fighters, guards, etc. Charging
or recharging from 230 V AC/50 Hz power network, or
12 V DC car socket.
Technical specification
Light source: 5 W LED (300 lm)
Light modes: 100 %, 75 %, 50 %, flashing, SOS flashing
Accumulator: Li-Ion 18650 3.7 V DC/1 800 mAh
Power adapter type E0421000:
input 110–240 V AC 50/60 Hz;
output 4.2 V DC/1 000 mA
Recharging from car: car adapter 12 V DC
Charging time: 3,5 hours (fully discharged cell)
Light duration (fully charged): 15 hours (non-stop)
Light range: 286 m
Flashlight operating temperature: -5 °C to +45 °C
Flashlight charging temperature: +5 °C to +45 °C
Flashlight size: 190 × 40 mm
Flashlight weight: 230 g
Recharging the accumulator
The flashlight's accumulator must be charged before first
use. Use the enclosed network adapter (type E0421000)
or car adapter. Charging a fully depleted accumulator
takes 3 hours. Charge the flashlight in dry indoor areas
at a temperature of +5 °C to +45 °C.
If the flashlight is not used for an extended period of
time, it is necessary to recharge the accumulator before
further use. The accumulator self-discharges and must
be recharged at least once every 3 months to prevent its
voltage from dropping and the accumulator potentially
being rendered unusable.
1. Connect power adapter type E0421000 to a
230 V~/50 Hz network.
2. Turn the switch on the flashlight to the off position – this
prevents damaging/destroying the accumulator.
3. Turn the rubber blank on the flashlight body until the
power connector is visible.
4. Connect the network power adapter to the flashlight's
power connector.
5. A red LED will light up on the power adapter while the
flashlight is charging. When the accumulator is fully
charged, the LED turns green.
6. Disconnect the power adapter from the flashlight
and the electrical network after charging is complete
and turn the rubber blank on the flashlight so that
water, humidity or dust cannot enter the interior of the
flashlight. Charging a fully depleted accumulator takes
approximately 3,5 hours.
7. The flashlight can also be recharged in a car – 12 V DC
through the lighter socket. Procedure for plugging in
and recharging is similar as when using a power adapter.
If the accumulator is fully discharged, recharge it using
a car adapter for a maximum of 3,5 hours. Disconnect
the adapter from the car socket after recharging.
The flashlight can be recharged using a car adapter only
when the vehicle is stationary and the engine is turned off.
Do not under any circumstances charge the flashlight when
the car engine is running or the car is in motion.
The LED light sources have a 50 000 hour service life and are
therefore not replaceable.
After exhausting, the entire flashlight can be disposed of.
Changing the accumulator
Turn off the flashlight before replacing the accumulator.
1. Remove the rear portion of the flashlight by turning it
anticlockwise.
2. Remove the accumulator pack and replace with a new
one with same dimensions and electrical parameters.
The new accumulator must be purchased only from the
manufacturer. Never use non-original components. Make
sure to observe the correct polarity when changing the
accumulator.
3. Reassemble the lantern by reversing the procedure for
disassembly.
WARNING
• When new, the flashlight must first be charged before use.
• The flashlight can be recharged using a car adapter only
when the vehicle is stationary and the engine is turned off.
Do not under any circumstances charge the flashlight when
the car engine is running or the car is in motion.
• The flashlight's accumulator must be kept charged to pre-
vent the voltage from dropping below the threshold level.
Therefore, it is recommended to recharge the flashlight at
least once every 3 months even when it is not being used.
Temperature for lamp ch5 °C to +45 °C.
• If the flashlight does not light up or the light is weak, im-
mediately recharge.
• If the accumulator is damaged or destroyed due to non-
observance of the above rules, complaints filed within the
warranty period regarding the flashlight (accumulator) will
not be accepted.
• Use the power adapter type E0421000 only for recharging
the lamp; do not recharge batteries not designed for the
purpose.
• Use the AC power adapter in dry indoor areas only.
• When replacing the accumulator, make sure to observe the
correct polarity.
• Do not throw the accumulator into a fire and do not disas-
semble or short-circuit it.
• After depletion, the accumulator becomes hazardous
waste. After depletion, do not dispose of the accumulator
in municipal waste. Turn the accumulator in at take-back
sites such as the shop where the flashlight was purchased.
• After the end of its service life, the entire flashlight must be
disposed of ecologically.
• If water enters the interior of the flashlight, remove the ac-
cumulator and dry the interior of the flashlight thoroughly.
Do not use the flashlight under any circumstances.
• The flashlight is not intended for use by persons whose
physical, sensory or mental disability or lack of experience
and expertise prevents its safe use, unless they are super-
vised or instructed in the use of the appliance by a person