28
‘
tESt
’: TEST MODE ACTIVATION
Allows to activate/deactivate the ‘Test’ mode for the selflearning of
the radio address in the receiver:
On
‘Test’ mode active
OFF
‘Test’ mode deactive
See the ‘Radio system set-up’ section for further details.
‘
AFr
’: ANTIFREEZE SETTING
The Antifreeze function allows you to select a minimum temperature
to be maintained when the chronostat is off, so as to protect both
the room and the equipment when the room temperature falls below
the set value.
The device leaves the factory with the Antifreeze function set on
3°C.
IMPORTANT: the function is active only when the device has
been set in the heating mode.
To set the Antifreeze temperature, carry out the following steps:
1.
Select the parameter ‘
AFr
’ and press the ‘
OK
’ button.
2.
The display will show the previously set Antifreeze temperature.
3.
Press buttons ‘ ’ and ‘ ‘ to change the setting (between OFF,
0.5°C..25°C); every change will be automatically memorized.
4.
To exit press the ‘
OK
’ button or else wait 10 seconds without
pressing any button.
‘MOrE’:
ADVANCED PARAMETERS MENU SETTINGS
The advanced parameters menu allows the installer to configure the
chonostat’s working.
To access the advanced parameters menu select the ‘MOrE’ parameter
and keep pressed for 2 seconds the ‘
OK
’ button, the display will show
the first advanced parameter. Pressing repeatedly the ‘
P
‘ button the
following advanced parameters will be scrolled:
‘OFS’
Room temperature offset
‘HISt’
Room temperature regulation hysteresis
‘tMIn’
Minimum output ON time
‘Entc’
External NTC sensor configuration
‘LinF’
Floor temperature lower limit
‘LSUP’
Floor temperature higher limit
Press the ‘
OK
’ button to display the value of the parameter. To
modify the selected parameter use the arrow buttons ‘ ’ and ‘ ’.
Press the ‘
OK
’ button again to save and go back or press ‘ ’ to
exit without saving the changes.
In any case the chonostat exits automatically after 20 seconds of
no buttons activity.
‘
OFS
’: ROOM TEMPERATURE OFFSET
With the Offset parameter it is possible to correct the temperature
reading by ±9.9 °C in order to correct any systematic reading errors
due to a positioning of the chronostat in areas unsuitable for room
WARNING
The chonostat is supplied with pre-set data for optimal
working. Modification of the advanced parameters must be
done only by qualified personnel.
- ENGLISH -