background image

21

GENERALITIES

This device is a battery-powered digital weekly chronostat for 

controlling room temperature on three levels: Comfort, Economy 

or Off/Antifreeze. 

Its main characteristic is the lack of electrical connections; indeed 

the ON and OFF signals are transmitted to the receiving unit by radio, 

making this device  easy and cheap to install, especially when there is 

no existing electrical system available.

The  chronostat  can  be  used  in  both  heating  and  air  conditioning 

systems  and  it  features  a  large  backlit  display  which  shows 

all  functional  indications,  the  program  schedule  and  the  room 

temperature reading or, alternatively, the current time.

It allows to set up to 7 different time schedules, each one different 

for each day of the week, with a minimum intervention time of 1/2 

hour during the 24 hours.

STARTING UP

When starting up for the first time open the battery lid and insert 

the batteries in the battery compartment 

O

 in Fig. 1, observing the 

polarities indicated.   The batteries must be alkaline 1.5V type AA.

If necessary carry out a reset operation by inserting a pointed object 

through  the  hole  provided  (

N

  in  Fig.  1); 

DO  NOT  USE  NEEDLES 

OR  TOOLS  THAT  COULD  IRREPARABLY  DAMAGE  THE 

CHRONOSTAT

.

The buttons present beneath the lower flap are  3:

OK

’: For programming the time and current day of the week (

I

 in          

Fig. 1);

‘    ‘:  Forward (

G

 in Fig. 1);

‘    ’:  Back (

L

 in Fig. 1);

Setting the current time and day

To set the clock of the chronostat carry out the following steps:

1.

 Open the flap of the battery compartment.

2.

 Keep  the  ‘

OK

’  button  pressed  for  at  least  2  seconds;  the  hour 

digits will start flashing.

3.

 Set the hour using buttons ‘    ‘ and ‘    ‘.

4.

 Confirm by pressing ‘

OK

’; the minute digits will start flashing.

5.

 Set the minutes using buttons ‘    ‘ and ‘    ‘.

6.

 Confirm by pressing ‘

OK

’; the box surrounding the current day of 

the week will start flashing.

7.

 Set the current day of the week using buttons ‘    ‘ and ‘    ‘ 

(the current day is highlighted by a box surrounding the number 

corresponding to the day of the week, 1 Monday .. 7 Sunday )

8.

 Confirm by pressing ‘

OK

’.

Setting the Heating / Cooling mode

The chronostat leaves the factory set in the heating mode.

The chronostat is factory set to heating mode. To modify the operating 

logic, keep the ‘    ‘ button pressed for at least 10 seconds.

A.

 If the chronostat was previously set on heating, the cooling mode 

will be set and the ‘    ‘ (fan)  symbol will flash on the display for 8 

seconds.

B.

 If the chronostat was previously set on cooling, the heating  mode 

will be set and the ‘    ‘ (flame) symbol will flash on the display for 

8 seconds.

- ENGLISH -

Содержание N CTA W

Страница 1: ...CRONOTERMOSTATO SETTIMANALE VIA RADIO WIRELESS WEEKLY CHRONOSTAT ...

Страница 2: ...ramming sets the regulation temperature into Economy mode E Button with double function In normal operation turns on and off the chronostat In schedule programming sets the regulation temperature into Off Antifreeze mode F Button with double function In normal operation displays current time or temperature In schedule programming sets the regulation temperature into Comfort mode G Forward button H...

Страница 3: ...mfort mode The chronostat is in programming mode Flashing Cleaning program active the remaining time is shown on the display Flashing Vacation program active the remaining time is shown on the display Fixed Indicates that the telephone interface is active Flashing Indicates that the remote command received by the telephone interface has been overridden by another local request through the chronost...

Страница 4: ...DLES OR TOOLS THAT COULD IRREPARABLY DAMAGE THE CHRONOSTAT The buttons present beneath the lower flap are 3 OK For programming the time and current day of the week I in Fig 1 Forward G in Fig 1 Back L in Fig 1 Setting the current time and day To set the clock of the chronostat carry out the following steps 1 Open the flap of the battery compartment 2 Keep the OK button pressed for at least 2 seconds...

Страница 5: ... to the receiver with a pause of 2 seconds between one and the next Everytime a command is trasmitted the symbol flashes on the display The Test mode can be exited in the user menu or switching off the chonostat by pressing the button In any case the Test mode will end automatically after approximately 17 minutes The Test mode must be used to self learn the address code of the chonostat on the rece...

Страница 6: ...23 INSTALLATION Fig 2 Fig 3 Method for releasing the wall mount plate from the base of the chronostat ENGLISH ...

Страница 7: ...he plate and then pressing downward on the device until the plastic teeth of the plate click into place then fix the chronostat body to the wall mount plate through the two screws supplied which must be mounted in the battery holder Fig 3 5 Insert the batteries in the battery compartment O in Fig 1 see paragraph HOW TO INSERT REPLACE THE BATTERIES WARNING To adjust properly room temperature install...

Страница 8: ...me schedule from 0 00 to 12 00 AM with half an hour steps while the dashes line in the bottom shows the time schedule from 12 00 to 24 00 PM The dashes show the operating mode of the chonostat Comfort Economy Off Antifreeze for every half an hour of the day as shown in the following P Economy mode one dash lit bottom Comfort mode two dashes lit Off Antifreeze mode no dashes lit Days of the week 1 ...

Страница 9: ...Comfort mode Economy mode 6 00 8 00 8 00 11 00 11 00 13 00 13 00 17 00 17 00 19 00 19 00 21 00 21 00 23 00 23 00 6 00 FIRST TIME SLOT Comfort mode Economy mode 6 00 23 00 23 00 6 00 SECOND TIME SLOT Comfort mode Economy mode 6 00 8 00 8 00 17 00 17 00 23 00 23 00 6 00 THIRD TIME SLOT Comfort mode Economy mode 6 00 8 00 8 00 11 00 11 00 13 00 13 00 17 00 17 00 23 00 23 00 6 00 3 Press the OK button...

Страница 10: ...the device will automatically exit the schedule programming mode QUICK GUIDE FOR SETTING THE TIME SCHEDULE Press button P The display shows PrOG with the icon turned on Press button OK The display shows dAY Press buttons and in order to choose one of the four days combinations available as pre set Press button OK to confirm the choice The display shows hour 00 00 with the relevant dash in the upsid...

Страница 11: ... SETTINGS The advanced parameters menu allows the installer to configure the chonostat s working Toaccesstheadvancedparametersmenuselectthe MOrE parameter and keep pressed for 2 seconds the OK button the display will show the first advanced parameter Pressing repeatedly the P button the following advanced parameters will be scrolled OFS Room temperature offset HISt Room temperature regulation hyster...

Страница 12: ...chronostat will be able to take into account a minimum and a maximum floor temperature limit during the room temperature regulation The parameter can be set with the following values no No external sensor wired rOOM External sensor wired to read room temperature FLOH External sensor wired to read floor temperature but it can not be shown on the display FLOS External sensor wired to read floor tempera...

Страница 13: ...he associated thermostats If the chronostat is regulating a comfort temperature the associated thermostatswillregulateaccordingtotheirsetpointknobtemperature instead if the chronostat is regulating an economy temperature the associated thermostats will regulate according to a reduction temperature which can be adjusted in the receiver Likewise if the chronostat is off with 5 C antifreeze function ...

Страница 14: ...ed and the chronostat is in heating mode the display will show also the symbol and the room temperature will be regulated according to the antifreeze value set in the relevant parameter see paragraph USER MENU SETTINGS HOW TO INSERT REPLACE BATTERIES The battery charge status is constantly displayed by means of the symbol The battery charge is at a maximum if all three level indicators are lit ins...

Страница 15: ...refore it is normal that the displayed temperature is not updated immediately and one need to wait up to 3 minutes to see the output switching On or Off Alternatively pressing OK button when in the main screen the user can force an update For the same reason at the expiry of the time schedule s half hour there will not be an immediate switch of the output it will be necessary to wait up to 3 minut...

Страница 16: ...sending an Off command if necessary 2 Send a command to the telephone interface to close the contact the chronostat will turn on 3 Using the functions of the telephone interface check that the contact is closed 4 Send a command to the telephone interface to open the contact the chronostat will turn off During this sequence no commands should be input with the control buttons as they have priority ...

Страница 17: ...o the remote sensor 15 m Antifreeze OFF 0 5 C 25 0 C Default 3 0 C Offset 5 0 C Default 0 0 C Backlight turns off 20 sec after the last pressing of a button Protection rating IP 30 Insulation class II Number of manual cycles 1 000 Operating temperature 0 C 40 C Storage temperature 10 C 50 C Humidity limits 20 80 RH non condensing Enclosure Material ABS PC V0 self extinguishing Colour Cover Signal ...

Страница 18: ..._______________________ ________________________________________ ________________________________________ ________________________________________ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 19: ... IST01540AAN 019584A0 200711 ...