10.
PROCEDURE TO FOLLOW IN THE EVENT OF A BREAKDOWN
−
CAUTION: NEVER carry out any work on the induction generators without first having disconnected them from the
power supply .
−
HAZARD: high voltage present in induction generators powered by the electricity supply .
−
The induction generators should only be opened by QUALIFIED, AUTHORISED PERSONNEL IN COMPLIANCE
WITH INTERNATIONAL, NATIONAL AND REGIONAL SAFETY LAWS AND REGULATIONS.
POSSIBLE CAUSE
STEPS TO BE TAKEN
Green LED off
Red LED off.
No power
Check that the generator is connected to
the power supply
Green LED on
Red LED off.
Make s u re you have turned the knob in
a clockwise direction
Turn the knob
Make s u re you have pos itionned the
suitable saucepan correctly
Pos ition a suitable saucepan correctly
Defect control form
Call a technician
Air inlet or outlet blocked.
Check and clean air inlet and outlet
Defective fan
Call a technician
Unsuitable saucepan
Use a suitable saucepan
E m p ty cooking protection triggered it to
cool down. The fan is o ver 220°C.
Verify that the generatur is power
supplied
Cooking point s e n s o r defective
Call a technician
Saucepan diam e ter under 160 m m
saucepan.
Use a suitable saucepan
Saucepan not pos itioned correctly and
thus not recognised
Pos ition the saucepan correctly
The power component is too hot and
has s w itched on the power reduction
autom a tically
Make s u re that the saucepan is s uitable.
Internal tem p e rature high due to
ins u fficient cooling
Unsuitable saucepan
Replace with a s u itable saucepan
Green LED on
Red LED on
Fas t increase in pyroceram
temperature. You m a y be us ing an
e m p ty saucepan
Adjus t the power on the bas is of the
quantity of food
Green LED flas h ing
Red LED off
Saucepan recognition not correctly
regulated
Call a technician
TYPE OF FAULT
Green LED flas h ing
Red LED off.
Poor heating
Green LED on
Red LED flashing
No heating
(the power part of the generator is too hot)
Green LED on
Red LED on
Green LED on
Red LED flashing
Heating of small metal objects on the zone
Green LED flas h ing
Red LED off.
No heating
No heating
(the induction component under the pyroceram is too hot)