Emmepi 702-IMD-3K Скачать руководство пользователя страница 1

INSTALLATION, OPERATING

AND MAINTENANCE INSTRUCTIONS

700 PROFESSIONAL

mixerset07

cat n° 38

INDUCTION COOKERS

V 400 / 3

GB

WOK-70     702-M-I-D     702-M-I     704-M-I

ESWOK-70     ES702-M-I-D     ES702-M-I     ES704-M-I

WOK-70-2P     WOK-70-6K     WOK-70-3K

702-IND-7K     702-IND-12K     702-IMD-3K     702-IND-6K

Содержание 702-IMD-3K

Страница 1: ...NANCE INSTRUCTIONS 700 PROFESSIONAL mixerset07 cat n 38 INDUCTION COOKERS V 400 3 GB WOK 70 702 M I D 702 M I 704 M I ESWOK 70 ES702 M I D ES702 M I ES704 M I WOK 70 2P WOK 70 6K WOK 70 3K 702 IND 7K...

Страница 2: ...the user or personnel responsible for use Page 11 1 7 Safety of the personnel responsible for use Page 12 1 8 Safety during installation maintenance and controls Page 12 1 9 Reproduction or use of un...

Страница 3: ...Page3 SYSTEMS PLAN V 400 3N WOK 70 702 M I D 702 M I 704 M I...

Страница 4: ...Page4 ESWOK 70 ES702 M I D ES702 M I ES704 M I V 400 3N...

Страница 5: ...Page5 V 400 3N WOK 70 2P WOK 70 6K WOK 70 3K 702 IND 7K 702 IND 12K 702 IND 3K 702 IND 6K...

Страница 6: ...it was designed The installation should be carried out by qualified personnel in compliance with the instructions provided by the manufacturer and with the regulations in force Never wash the applianc...

Страница 7: ...tics The manufacturing co declines any responsability for damages caused directly or indirectly due to erroneous assembly tampering bad maintenance lack of skill N B If the equipment is placed against...

Страница 8: ...00x900H 2 3 6 400 3N T 50 60 106 0 76 WOK 70 3K 400x1400x900H 1 3 3 400 3N T 50 60 106 0 76 702 IND 7K 400x1400x900H 2 3 5 7 400 3N T 50 60 106 0 76 702 IND 12K 400x1400x900H 2 6 12 400 3N T 50 60 106...

Страница 9: ...g Remove the protection film and clean the eventual glue marks with petrol or kerosene don t smoke carry out the operation away from heat sources Do not spread in the environment or leave at children...

Страница 10: ...used by the non earthing of the installation The appliance is to be furthermore included in an equipotential system whose efficiency must be checked following the regulations in force All equipments w...

Страница 11: ...el responsible for installing commission using and maintaining the appliance must be QUALIFIED or AUTHORISED by the manufacturer 1 4 HAZARDS CAUSED BY FAILURE TO OBSERVE THE SAFETY REGULATIONS Failure...

Страница 12: ...ctricity supply Do not touch any of the internal parts of the induction generator 1 8 SAFETYDURING INSTALLATION MAINTENANCEAND CONTROLS The personnel responsible for use must be qualified All installa...

Страница 13: ...TA Type RELD V3S R6000 R6000 Power KW 12000 Watt Voltage VAC 400 VAC 3F N T Current A 8 6Amp re Frequency HZ 50 60 Hz Dimensions See technical layouts Thickness ceramic glass 6 mm Derating insertion 0...

Страница 14: ...tors must be considered components and not finished products so you must respect the laws the regulations and the standards in force in the different countries as far as low and medium voltage are con...

Страница 15: ...are still powered even when the cooker is switched off Therefore if carrying out maintenance work disconnect the appliance from the power supply first Make sure that no liquid penetrates the induction...

Страница 16: ...y cooking protection triggered it to cool down The fan is over 220 C Verify that the generatur is power supplied Cooking point sensor defective Call a technician Saucepan diameter under 160 m m saucep...

Страница 17: ...mpliance with the regional national international regulations in force in the different countries as far as junk removal is concerned Avoid improper use The components of induction generators must not...