34
=
=
i
When count value reaches the Set Value, Output Position is changed. If
Output Pulse time is not 0, then Output Position is changed
at the end of the Pulse time and Real counting value is
shown
on Actual
value screen. If output pulse time then, output
position has not change
until
Manual Reset happens.
When counting value reach SET value, output position becomes active
position and if the Start input is active, then count value starts counting
from 0 value. But SET value is observed in actual value display.
Counting process has not continue over SET value.
When Manual Reset happens, count value becomes 0 value.
Counting direction : 0 --> P (Upcounting)
=
Automatic Reset-3
=
0
Set
Reset
Output
Start
0
Set
Reset
Output
Start
If output functions parameter is selected Automatic Reset (
, or , then must be different from zero
for realizing Automatic Reset.