background image

17

 3.5.2 Switch Connection

1

3

2

4

5

P

A

U

S

E

R

E

S

E

T

S

w

it

c

h

S

w

it

c

h

1

3

2

4

5

P

A

U

S

E

R

E

S

E

T

NOTE-1

S

w

it

c

h

S

w

it

c

h

NOTE-1

0

 V

 

Z

1

2

 V

 

Z

M

a

x

5

0

m

A

0

 V

 

Z

1

2

 V

 

Z

M

a

x

5

0

m

A

S

w

it

c

h

S

T

A

R

T

S

w

it

c

h

S

T

A

R

T

=

=

PNP type operation

NPN type operation

NOTE-1 : Sensor supply voltage: 12V

Z

 ± 40%,   50 mA maximum with short circuit 

protection

Содержание EZM-7735

Страница 1: ...r 6 digits Process PV and 6 digits Set SV Value Display Operation with 1 Set Value Reset Pause and Start Inputs Operation with Automatic and Manual Reset NPN PNP Type Operation EZM 7735 72 x 72 DIN Un...

Страница 2: ...ce to the system are explained Operation and Parameters In this section user interface of the device how to access to the parameters description of parameters are explained Also in these sections ther...

Страница 3: ...3 5 INPUT CONNECTION 3 5 1 PROXIMITY CONNECTION 3 5 2 SWITCH CONNECTION 3 6 RELAY OUTPUT WIRING DIAGRAM 3 7 GALVANIC ISOLATION TEST VALUES OF EZM 7735 PROGRAMMABLE TIMER 4 DEFINITION OF FRONT PANEL A...

Страница 4: ...o the following directives 2006 95 EC The Low Voltage Directive 2004 108 EC The Electromagnetic Compatibility Directive has been designed and manufactured to the following specifications EN 61000 6 4...

Страница 5: ...control rollers and can be adapted easily to all mechanical construction and automation system Some application fields which they are used are below Standart EZM 7735 Standart Supply Voltage Input 230...

Страница 6: ...vered is free from defects in material and workmanship This warranty is provided for a period of two years The warranty period starts from the delivery date This warranty is in force if duty and respo...

Страница 7: ...the power off until all of the wiring is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the unit may...

Страница 8: ...inch OP SV O2 S2 Timer EZM 7735 RESET P SET OP V S 2 O S2 i T er m Z 735 E M 7 E ET R S P SET Maximum 15 mm 0 59 inch 84 mm 3 31 inch 11 5 1 mm 0 45 inch Front Panel IP65 protection NEMA 4X Panel sur...

Страница 9: ...10 2 3 Panel Cut out 9 97 mm 3 82 inch min 69 mm 2 72 inch 69 mm 2 72 inch 97 mm 3 82 inch min...

Страница 10: ...at the cut out is the right size 2 Check front panel gasket position 3 Insert the device through the cut out If the mounting clamps are on the unit put out them before inserting the unit to the panel...

Страница 11: ...e will not fall while doing the montage The unit is designed for panel mounting 1 Insert the unit in the panel cut out from the front side 2 Insert the mounting clamps to the holes that located top an...

Страница 12: ...ing to the system s needs Only qualified personnel and technicians should work on this equipment This equipment contains internal circuits with voltage dangerous to human life There is severe danger f...

Страница 13: ...nnel injury Inputs Sensor Supply Voltage Max 50mA PAUSE RESET 12 V Z 0 V Z Supply Voltage Input It must be determined in order 230V V 15 10 50 60Hz 2 3VA 115V V 15 10 50 60Hz 2 3VA 24 V V 15 10 50 60H...

Страница 14: ...3 3 View of Device Label 14 a a P N EZM 7735 1 2 3 4 5 18 19 20 21 22 N L 230V V 15 10 50 60Hz 2 3VA 5A 250VV NC C NO 12 V Z Max 50mA 0 V Z Reset Pause Y ca Start...

Страница 15: ...ge must be applied to the unit Controlling prevents damages in unit and system and possible accidents as a result of incorrect supply voltage There is no power supply switch on the device So a power s...

Страница 16: ...2 V Z Max 50mA 0 V Z PAUSE PROX PROX RESET PNP PNP PROX PNP START NOTE 1 1 3 2 4 5 12 V Z Max 50mA 0 V Z PAUSE PROX PROX RESET NPN NPN PROX NPN START PNP type operation NPN type operation NOTE 1 Senso...

Страница 17: ...itch Switch 1 3 2 4 5 PAUSE RESET NOTE 1 Switch Switch NOTE 1 0 V Z 12 V Z Max 50mA 0 V Z 12 V Z Max 50mA Switch START Switch START PNP type operation NPN type operation NOTE 1 Sensor supply voltage 1...

Страница 18: ...ammable Counter Supply Voltage 500V V for EZM 7735 3 2000V V for EZM 7735 5 12V Z Sensor Supply Voltage Relay Outout 3 6 Relay Output Wiring Diagram Fuse Load Last Control Element Contactor 5A V T Fus...

Страница 19: ...NT Button is used to Reset the Actual Value or increment the digit value that is selected by SHIFTING Button ENTER Button is used for saving all changes to memory and accessing to the parameters SHIFT...

Страница 20: ...power is applied to the device software revision number of the controller is on actual value display Then operation screen is observed momentarily illuminated rEu Revision If there is an unexpected s...

Страница 21: ...SV O2 S2 OP SV O2 S2 OP SV O2 S2 RESET P SET Operation Screen SET Screen SET Screen SET Screen Operation Screen SET Screen When shift button is pressed 6th digit of SET value starts to flash Press Shi...

Страница 22: ...RESET in parameters section At the end of MANUAL RESET if then Count value becomes 0 value If then Count value becomes SET value 4 4 Resetting the Count Value When RESET button is pressed Actual Valu...

Страница 23: ...eter flashes Press Enter Button Filter time for Reset Pause and Start Input You can change the p a r a m e t e r w i t h INCREMENT button save it to the memory and p a s s t o t h e n e x t parameter...

Страница 24: ...he p a r a m e t e r w i t h INCREMENT button save it to the memory and p a s s t o t h e n e x t parameter with ENTER button Press Enter Button Press PROG button to exit from programming section with...

Страница 25: ...G button to exit from programming section without doing any changes You can change the p a r a m e t e r w i t h INCREMENT button save it to the memory and p a s s t o t h e n e x t parameter with ENT...

Страница 26: ...26 Continue to press ENTER button for scanning all parameters Time Unit and Scale Selection Operation Screen OP SV O2 S2 OP SV O2 S2 RESET P SET OP SV O2 S2 OP SV O2 S2 RESET P SET...

Страница 27: ...me It can be adjusted from to msec 8 PARAMETRELER 5 Program Parameters Time Unit and Scale Selection Hour Minute It can be adjusted from to Minute Second It can be adjusted from to Second Milisecond I...

Страница 28: ...es while Start input is active When Start input is passive count value becomes 0 When Manual Reset happens count value becomes 0 value Counting direction P 0 Downcounting When count value reaches the...

Страница 29: ...ens count value becomes 0 value Counting is continues while Start input is active When Start input is passive count value becomes 0 Counting direction P 0 Downcounting When count value reaches the 0 O...

Страница 30: ...the SET value When Manual Reset happens count value becomes 0 value When Start input is passive count value becomes 0 Counting direction P 0 Downcounting When count value reaches the 0 Value Output P...

Страница 31: ...mes 0 value When count value reaches the 0 Value Output Position is changed Actual value is reset automatically If Start input is active then counting starts downcounting at Set value If Output Pulse...

Страница 32: ...nput is active then counting starts from 0 value If output pulse time is 0 then output position has not change until Manual Reset happens Actual counting value stops at SET value Counting process is n...

Страница 33: ...ive then counting starts from Set value If output pulse time is 0 then output position has not change until Manual Reset happens Actual counting value stops at 0 value Counting process is not continue...

Страница 34: ...alue reach SET value output position becomes active position and if the Start input is active then count value starts counting from 0 value But SET value is observed in actual value display Counting p...

Страница 35: ...until Manual Reset happens When counting value reach 0 value output position becomes active position and if the Start input is active then count value starts counting from Set value But 0 value is ob...

Страница 36: ...has not change until Manual Reset happens When counting value reach Set value output position becomes active position If the Start input is active then counting continue over the Set value When Manua...

Страница 37: ...sition If output pulse time then output position has not change until Manual Reset happens When counting value reach 0 value output position becomes active position If the Start input is active then c...

Страница 38: ...position When manual reset happens count value becomes SET value If the Start input is active then Process starts counting until count value reach SET value When count value reach SET value Output Pos...

Страница 39: ...e screen Sensor Type Selection NPN type sensor selected PNP type sensor selected Reset and Set Protection for Front Panel Access Only RESETButton protection is active Actual value can not be reset by...

Страница 40: ...play If program password is not 0 while accessing to the program parameters 1 If user does not enter the value correctly operation screen will appear without entering to operator parameters 2 When in...

Страница 41: ...t significant digit of the parameter flashes But if the password is not entered flashing of the most significant digit is not realised When PROG button is pressed password entering screen will appear...

Страница 42: ...warning and reset the count value press RESETbutton 2 If Actual Value is flashing and counting is stopped It appears if any of the count value is greater than the maximum count value To remove this wa...

Страница 43: ...trical Characteristics Rated voltage 16 VZ 5mA Maximum continuous permissible voltage 30 VZ Logic 1 minimum level 3 VZ Logic 0 maximum level 2 VZ Sensor Supply Voltage Electrical Characteristics 12VZ...

Отзывы: