12. ALARM STATUS PAGES
ALARM STATUS pages are used to see and clear alarms. If a new alarm is occured then alarm relay and
alarm led becomes ON. To switch OFF the alarm relay and alarm led, ALARM STATUS pages are accessed.
If an alarm is occured(for example ALARM1 is ON) then;
Push button to access to ALARM STATUS 1 page and clear ALARM1
alarm.
Push button to access to ALARM STATUS 2 page.
Push button to clear alarm output, alarm led and return to the
PROCESS VALUES page.
19.07.06 14:30:21
HOUSE
20.2°C
OUT
12.1°C
HUMIDITY
65%
DAY -5
ALARM
ON
OFF
TIME[SEC]
ALARM STATUS
ON
OFF
TIME[SEC]
ALARM STATUS
ON
OFF
TIME[SEC]
11. ALARM TYPES: NONLATCH, CYCLIC and LATCH
ALARM SET VALUES
TYPE = NONLATCH
ALARM SET VALUES
TYPE = LATCH
9. ROOM2 OFL alarm
If ROOM2 sensor is broken while EPC is working then
ALARM STATUS 2
ROOM2 OFL alarm is switched
ON.
10. OUTSIDE OFL alarm
If OUTSIDE sensor is broken while EPC is working then
ALARM STATUS 2
OUTSIDE OFL alarm is switched
ON.
ALARM STATUS
ON
OFF
TIME[SEC]
ALARM SET VALUES
TYPE = CYCLIC
ALARM STATUS 1
ABSOLUTE MIN :OFF
ABSOLUTE MAX :OFF
DIFFERENTIAL :OFF
ALARM1 :OFF
NEGATIVE PRESSURE:OFF
HUMIDITY SENSOR :OFF
NO ENOUGH FEED :OFF
ALARM STATUS 2
ROOM1 OFL :OFF
ROOM2 OFL :OFF
OUTSIDE OFL :OFF
32
7. NO ENOUGH FEED alarm
EPC always controls the silo just before to run a step. If
FEED UNIT PARAMETERS
UNIT parameter is
WEIGHT and there is not enough feed in silo to run the step then
ALARM STATUS 1
NO ENOUGH FEED
alarm is switched ON.
8. ROOM1 OFL alarm
If ROOM1 sensor is broken while EPC is working then
ALARM STATUS 2
ROOM1 OFL alarm is switched
ON.