MAXVNTCURVE/MAXVNT:
If curve is enabled;
MAXVNTCURVE
= Max. Ventilation set value from curve,
If curve is disabled;
MAXVNT
=
SET VALUES PAGE
VENT. MAX set value,
MINVNTCURVE/MINVNT:
If curve is enabled;
MINVNTCURVE
= Min. Ventilation set value from curve,
If curve is disabled;
MINVNT
=
SET VALUES PAGE
VENT. MIN set value,
TMPSETCURVE/TMPSET:
If curve is enabled;
TMPSETCURVE
= HOUSE TEMP set value from curve,
If curve is disabled;
TMPSET
=
SET VALUES PAGE
TEMP.HOUSE set value.
ROOM1 TEMP:
ROOM1 SENSOR reading temperature value.
ROOM2 TEMP:
ROOM2 SENSOR reading temperature value.
OUTSIDE TMP:
OUTSIDE SENSOR reading temperature value.
5.4.2 SYSTEM MONITORING
SYSTEM MONITORING
TMPSETCURVE: 20.0°C
ROOM1 TEMP : 15.1°C
ROOM2 TEMP : 19.4°C
OUTSIDE TMP: 25.3°C
MAXVNTCURVE: 8%00
MINVNTCURVE: 0%00
TUNNEL VENT: 0%00
SYSTEM MONITORING
TMPSET: 20.0°C
ROOM1 TEMP : 15.1°C
ROOM2 TEMP : 19.4°C
OUTSIDE TMP: 25.3°C
MAXVNT : 8%00
MINVNT : 0%00
TUNNEL VENT: 0%00
SYSTEM MONITORING
TMPSETCURVE: 20.0°C
ROOM1 TEMP : 15.1°C
ROOM2 TEMP : 19.4°C
MAXVNTCURVE: 8%00
MINVNTCURVE: 0%00
TUNNEL VENT: 0%00
SYSTEM MONITORING
TMPSET: 20.0°C
ROOM1 TEMP : 15.1°C
ROOM2 TEMP : 19.4°C
MAXVNT : 8%00
MINVNT : 0%00
TUNNEL VENT: 0%00
SYSTEM MONITORING page has four different screens. All screens are seen below;
CONTROL FUNC PAGE 1 PAGE
CURVE parameter is enabled,
CONTROL FUNC PAGE 1 PAGE
OUTSIDE TEMP parameter is enabled.
CONTROL FUNC PAGE 1
PAGE CURVE parameter is disabled,
CONTROL FUNC PAGE 1 PAGE
OUTSIDE TEMP parameter is enabled.
CONTROL FUNC PAGE 1 PAGE
CURVE parameter is enabled,
CONTROL FUNC PAGE 1 PAGE
OUTSIDE TEMP parameter is disabled.
CONTROL FUNC PAGE 1 PAGE
CURVE parameter is disabled,
CONTROL FUNC PAGE 1 PAGE
OUTSIDE TEMP parameter is disabled.
FEEDING CONSUMPTION
03.07.06 02:11:27
TARE : NO
RESET CONSUM: NO
REQUIREDFEED: 151KG
EXIST FEED : 368KG
TOTAL CONSUM: 8400KG
DAY NUMBER : 12
TARE:
Tare enable parameter (Range: NO- YES / Factory Setting: NO).
RESET CONSUM:
(Range: NO- YES / Factory Setting: NO).
To reset
FEEDING CONSUMPTION
TOTAL CONSUM parameter, please change
FEEDING CONSUMPTION
RESET CONSUM parameter from NO to YES and push button, after that the
FEEDING CONSUMPTION
TOTAL CONSUM parameter will reset and
FEEDING CONSUMPTION
REST CONSUM parameter will change from YES to NO.
Also, curve enable event will reset
FEEDING CONSUMPTION
TOTAL CONSUM parameter.
REQUIREDFEED:
Required feed amount to terminate step.
EXIST FEED:
Feed weigh in silo.
TOTAL CONSUM:
Total feed consumption at the active curve.
DAY NUMBER:
Day Number.
5.4.3 FEEDING CONSUMPTION (EPC 3&4)
23
(NOTE-1)
(NOTE-1)
(NOTE-1)
(NOTE-1)
NOTE-1:
If
VENTIL.PARAMETERS PAGE
FAN CONT. Parameter is TUNNEL, then TUNNEL VENT is shown. If the
parameter value is BASIC&TUN. and the ventilation level is basic ventilation, then BASIC VENT is shown. If the
parameter value is BASIC&TUN. and the ventilation level is tunnel ventilation, then TUNNEL VENT is shown.