HR:MN (COLUMN):
Step start time
(Range: 00:00 - 23:59 / Factory Setting: 00:00).
FEED <KG> (COLUMN):
Feed amount for related step
(Range: 0 KG - 10000 KG / Factory Settings please look below).
Push button to access to ALARM SET VALUES PAGE (If no parameter is selected)
Push button to access to PROCESS VALUES PAGE (If no parameter is selected)
Push button to change parameter (If no parameter is selected)
Push button to access to LIGHTING PARAMETERS PAGE (If the last parameter is selected)
5.4.9 FEEDING PARAMETERS (EPC 3&4)
FEEDING PARAMETERS
F1: 00:00 0
F2: 00:00 0
F3: 00:00 0
F4: 00:00 0
F5: 00:00 0
HR:MN FEED<KG>
Start Time
Feed Amount
Depend on sample screen above;
EPC gives;
At 06:00: 150kg feed (F1 step)
At 10:00: 200kg feed (F2 step)
At 12:00: 100kg feed (F3 step)
At 19:00: 100kg feed (F4 step)
At 22:00: 200kg feed (F5 step)
Important :As long as a running step is not completed EPC will not run next step, even if next step’s start time
is reached. So all steps must be entered properly.
FEEDING PARAMETERS
F1: 06:00 150
F2: 10:00 200
F3: 12:00 100
F4: 19:00 100
F5: 22:00 200
HR:MN FEED<KG>
Start Time
Feed Amount
FEEDING PARAMETERS
F1: 00:00 600
F2: 07:00 0
F3: 00:00 0
F4: 00:00 0
F5: 00:00 0
HR:MN FEED<KG>
5.4.9.1 FEEDING FUNCTION (EPC 3&4)
28