SETTING THE RESISTANCE LIMITS

1.  Access the Administrator Menu by entering an 

administrator ID number and PIN on the keypad. 

2.  Tap the Preferences button. 

4.  Adjust the Wrist Strap and Footwear Limits by 

tapping the < and > buttons. Tap the Save button 

when complete.

Figure 16.  Locating the Preferences button in the Admin 

Menu

3.  Tap the ESD Test button. 

Figure 17.  Locating the ESD Test button in the 

Preferences Menu

Figure 18.  Locating the Wrist and Foot Limits in the 

ESD Test Menu

TEAM5 Software

When used with the EMIT SmartLog™, 

TEAM5 allows manufacturers and 

assemblers to automate the collection 

of employee ESD testing. It has a set of 

robust employee management functions 

that allows automated tracking of employee leave time, 

shift and department assignments and ESD training. 

TEAM5 connects your ESD test data to the rest of your 

manufacturing environment with automated electronic 

data interchange in a variety of formats.
TEAM5 Software is required for every SmartLog system 

installation. TEAM5 is compatible with the SmartLog 

V5™ and SmartLog Pro® systems.
See the 

TEAM5 User Manual

 for more information.

The software may be downloaded using the following 

link:

http://emit.descoindustries.com/team5.aspx

NOTE: A license dongle is required to run the software. 

Contact EMIT Customer Service to schedule an 

installation session.

Содержание 50780 SmartLog Pro

Страница 1: ...mated reports that may be e mailed to track short term and long term corrective actions Test limits and test parameters wrist strap only footwear only wrist strap and footwear etc may be customized wi...

Страница 2: ...DescoEMIT com Contents 3 System Overview 4 Items and Accessories 4 Packaging 5 Features and Components 6 Installation 6 Hardware Setup 7 10mm Wrist Cord Adapter 8 Relay Terminal 8 Network Setup 9 Tes...

Страница 3: ...site DescoEMIT com System Overview SmartLog Pro SmartLog Pro PC with TEAM5 Software Supervisor Department Manager Department Manager Department Manager Figure 2 Illustration of the SmartLog Pro System...

Страница 4: ...787 Replacement Foot Plate Cable 50788 Handheld QR Code Scanner USB Use the SmartLog Pro along with the TEAM5 Software to automate the collection of employee ESD testing This software is offered in tw...

Страница 5: ...12 2018 DESCO INDUSTRIES INC Employee Owned EMIT 3651 Walnut Avenue Chino CA 91710 909 664 9980 Website DescoEMIT com Features and Components Figure 3 SmartLog Pro features and components A B C D E F...

Страница 6: ...egrates with electronic door locks lights buzzers etc See Relay Terminal on page 8 for more information N Ground Terminal Secure the tinned wire termination of the included ground cord to this termina...

Страница 7: ...face of the SmartLog Pro Be sure to clear the clip at the base of the plunger s shaft when inserting into the jack 6 Connect the SmartLog Pro to the bracket Use the included thumbscrew to secure the...

Страница 8: ...tLog Pro to a local area network LAN using its Ethernet communication module DYNAMIC IP PROCEDURE 1 Verify that the Ethernet cable is securely connected to your network and SmartLog Pro The LEDs on th...

Страница 9: ...te of this address as it will be required to establish communication between the SmartLog Pro and the TEAM5 Server Software Figure 13 Locating the IP address in the Admin Menu Figure 14 Locating the N...

Страница 10: ...When used with the EMIT SmartLog TEAM5 allows manufacturers and assemblers to automate the collection of employee ESD testing It has a set of robust employee management functions that allows automated...

Страница 11: ...lean with 99 isopropyl alcohol when using the 1 Gigohm high test limit A dirty foot plate could yield a false pass When performing a wrist strap test be sure to completely plug in the wrist cord into...

Страница 12: ...umidity sensor embedded within the SmartLog Pro Figure 22 EMIT 50424 Limit Comparator Figure 23 EMIT 50784 5 Pound Electrode for Limit Comparator Specifications SmartLog Pro Input Voltage and Frequenc...

Отзывы: