S1CG/S1HG
Single-Zone,
S2CG/S2HG
Dual-Zone
• Installation, Operation and Maintenance Manual •
P/N 240007754, Rev. C [3/19/2010]
37
Made in the USA
Specifi cation and Dimensions
(continued)
(see NOTICE on page 33 )
S2HG electrical specifi cations
Table 16
Capacity Volts/HZ/PH
Fan motor
Compressor
Total
amps
Min
volt
M.C.A.
HACR
BRKR
Circuit #1
Circuit #2
AMPS
HP
RLA
LRA
RLA
LRA
9900
208/230/60/1
0.8
0.125
3.9
20
3.9
20
7.8
197
8.7
15
9200
208/230/60/1
0.8
0.125
3.9
20
5.2
27
8.8
197
10
15
2200
208/230/60/1
0.8
0.125
5.2
27
5.2
27
9.8
197
11
15
S2HG
performance data: Matched with EMI Series Indoor Units
Heat pump systems with wall units
Table 17
Wall units
Condenser
Cooling
Btuh
Heating
Btuh
SEER
HSPF
SHR
EER
COP
Ref.
WLHG09
S2HG99
18,000
17,400
13.0
7.7
0.73
12.1
3.2
R410A
WLHG12
S2HG22
24,000
21,000
13.0
7.7
0.68
12.0
3.2
R410A
WLHG12
S2HG92
21,000
19,200
13.0
7.7
0.70
12.0
3.2
R410A
Heat pump systems with universal units
Table 18
Air handlers
Condenser
Cooling
Btuh
Heating
Btuh
SEER
HSPF
SHR
EER
COP
Ref.
UNHG09
S2HG99
18,000
17,400
13.0
7.7
0.73
12.1
3.2
R410A
UNHG12
S2HG22
24,000
21,000
13.0
7.7
0.68
12.0
3.2
R410A
UNHG12
S2HG92
21,000
19,200
13.0
7.7
0.70
12.0
3.2
R410A
S2CG/S2HG
Dual zone
WLC/WLH
UNC/UNH