EM Service Manual
www.emerymark.com
56
2.4 Machine alarms
DOOR OPEN
SYSTEM BLOCKED
The machine is working correctly.
In case the machine fails, in this window the fault alerts are issued,
and they are the following:
SYSTEM
OK
HIGH PRESSURE
FAILURE
LOW PRESSURE
FAILURE
PROBABLE CAUSE
SOLUTION
1.
For safety the machine cannot work
with the door open.
1.
Close the door to continue.
(If it is closed and the alarm still appears,
contact your dealer).
Water cooled:
1.
Problems with the tower cooling: it is
off, low water level, lack of maintenance
(scale).
2.
Lack of water supply.
Air cooled:
1.
Lack of ventilation.
2.
High ambient temperature.
3.
Lack of maintenance of the condenser.
4.
Damaged fan.
Water cooled:
1.
Check the cooling tower, verify that it is
turned on, filled with water, if maintenan
-
ce is necessary.
2.
Check the water supply.
Air cooled:
1.
Place the machine in a space suitable
where you can have the correct ventilation.
2.
Lower the ambient temperature to the
proper levels for the machine.
3.
Check the condenser for dust.
4.
Seek technical advice.
1.
The ice cream froze.
2.
Gas leak.
1.
Remove the ice cream, wait a few
minutes for the alarm to clear.
2.
If the machine does not cool down,
the ice cream does not come out with the
proper consistency and it is constantly
protected with this alarm, it is likely that
there is a gas leak, in this case it requires
technical support.
Содержание EM 10
Страница 3: ...3 ESPAÑOL ENGLISH FRANÇAIS 4 40 41 77 78 114 ...
Страница 27: ...27 Mantenimiento EM 20 14 15 13 EM 40 16 ...
Страница 29: ...29 Mantenimiento 3 1 6 Circuito electrónico EM 10 4 3 2 1 5 ...
Страница 35: ...35 Mantenimiento EM 10 y EM 20 Aire Monofásicas ...
Страница 36: ...www emerymark com 36 Manual de Servicio EM EM 10 EM 20 y EM 40 Agua Trifásicas ...
Страница 63: ...63 EM 10 8 9 1 12 11 10 4 6 5 7 3 2 3 1 5 Electric and refrigeration components Maintenance ...
Страница 64: ...EM Service Manual www emerymark com 64 EM 20 14 15 13 EM 40 16 ...
Страница 66: ...EM Service Manual www emerymark com 66 3 1 6 Electronic circuit EM 10 4 3 2 1 5 ...
Страница 72: ...EM Service Manual www emerymark com 72 EM 10 and EM 20 Air Single phase ...
Страница 74: ...EM Service Manual www emerymark com 74 EM 10 EM 20 and EM 40 Water Three phase ...
Страница 101: ...101 EM 20 14 15 13 EM 40 16 Entretien ...
Страница 103: ...103 3 1 6 Circuit electronique EM 10 4 3 2 1 5 Entretien ...
Страница 109: ...109 EM 10 et EM 20 Air triphasée Entretien ...
Страница 110: ...Manuel d entretien EM www emerymark com 110 EM 10 EM 20 et EM 40 Eau triphasée ...
Страница 115: ...115 ...