~ 17 ~
v. 1.23
Section 6: CARE and MAINTENANCE
(Cont’d)
machine. It can be cleaned using a strong (shop-type) vacuum
cleaner with a soft brush attached.
The following parts are wearable and should be inspected at least
weekly:
DIAGRAM 5-A
APPROX. LIFE
Part # SEAL011 - o-ring, square, inside rear bushing 1,000 hrs./ 1 year
Part # SPRG005 - blade Springs ................................2,000 hrs./2 years
Part # BRNG002 - bearing, dasher front.................... 2,000 hrs./2 years
Part # BLAD010 - blade, scraping...........................5,000 hrs./4.5 years
Part # SEAL013 - o-ring, gate ...................................1,000 hrs./ 1 year
Part # FAST024 - washer, Teflon...............................1,000 hrs./ 1 year
Part # SEAL012 - o-ring, door seal ..........................4,000 hrs./ 4 years
Part # SPRG006 - spring, gate pressure ...................4,000 hrs./ 4 years
If your batch freezer has been stored in an unheated area and is
brought into a warm area for use, allow it to sit for at least 12 hours
in the warmer temperature; condensation could build up on cold
surfaces.
Never transport, store, or use your machine in any position other
than upright on its feet; Oil in the refrigeration system could
travels into areas of the machine's piping where it could remain
trapped.
Your machine has been tested and is rated for use in ambient air
temperatures as high as 104 degrees Fahrenheit, and as low as 50
degrees Fahrenheit. Operation in temperatures at the high end of
capacity may slightly increase freezing time and vice versa at the
cold end.