background image

Type Y696

6

*Recommended spare part.

10.  Install the parts on the pusher post in the order 

listed below:

      •  Diaphragm plate gasket (key 7)

      •  Lower diaphragm plate (key 6)

      •   Diaphragm and plate assembly (key 5) pattern 

 

side up

      •  Control spring seat (key 4)

11.  Insert and tighten the diaphragm cap screw 

(key 30) to secure the diaphragm parts to the 

pusher post (key 8).

12.  Install the assembled parts in the lower casing 

(key 20). Make sure that the lever (key 9) fits in 

the pusher post (key 8) and that the holes in the 

diaphragm align with the holes in the lower casing.

13.  Install the spring case (key 23) on the lower casing 

assembly (key 20) so that the vent assembly 

(key 56) is correctly oriented and secure with 

the cap screws (key 21) and hex nuts (key 22) 

fingertight only.

14.  Place the spring (key 1) in the spring case 

assembly (key 23), then install the upper spring 

seat (key 44) and the adjusting screw (key 2).

15.  Turn the adjusting screw (key 2) clockwise until 

there is enough control spring (key 1) force to 

provide proper slack to the diaphragm (key 5). 

Using a crisscross pattern, finish tightening the 

cap screws (key 21) and hex nuts (key 22) to 15 

to 20 ft-lbs / 20 to 27 N•m of torque. To adjust the 

outlet pressure to the desired setting, refer to the 

Startup and Adjustment section.

16.  Install a replacement closing cap gasket (key 35) if 

necessary and then install the closing cap (key 3).

Parts Ordering

When contacting your local Sales Office about this 

regulator, include the type number and all other 

pertinent information stamped on the nameplate. 

Specify the complete 11-character part number from the 

following parts list when ordering replacement parts.

Parts list

In this parts list, parts marked NACE are intended 

for corrosion-resistant service as detailed in the 

NACE International Standards MR0175 

and MR0103.

Type Y696 Regulator (Figure 3)

Key  Description 

Part number

  1  

Control Spring, Plated steel  

See Table 2

  2  

Adjusting Screw, Zinc  

1A5896X0022

  3  

Closing Cap

 

  Zinc  

1A589544022

 

  Steel  

1J880124092

  4  

Lower Control Spring Seat, Zinc  

0X014744012

  5*   Diaphragm

 

  Nitrile (NBR) 

 0R032502072

 

  Fluorocarbon (FKM) 

0R0325X0032

  6  

Lower Diaphragm Plate

 

  Stainless steel 

 0V003935032

 

  Stainless steel (NACE) 

 0V0039X0022

  7  

Diaphragm Plate Gasket, Composition  

1A348704022

  8  

Pusher Post, Stainless steel (NACE)  

0Y096435072

  9  

Lever Assembly

 

  Stainless steel  

1E3409000B2

 

  Stainless steel (NACE)  

1E3409X0012

  11   Machine Screw (2 required)

 

  Stainless steel  

1A866935032

 

  Stainless steel (NACE)  

1A8669X0012

  13   Stem

 

  Stainless steel  

1A630935032

 

  Stainless steel (NACE)  

1A630935032

  14*  Cotter Pin

 

  Stainless steel  

1A866537022

 

  Stainless steel (NACE)  

1A8665X00A2

  16*   Body Gasket, Composition  

1A348004032

  17   Split Ring, Zinc-plated steel  

0Y095828982

  19   Union Nut

 

  Cast iron  

0Z0176X0032

 

  Steel  

0Z017624092

 

  Stainless steel  

0Z0176X0012

  20   Lower Casing

 

  Cast iron  

3B973519012

 

 Steel 

3F191622012

 

  Stainless steel  

3F191633092

  21   Diaphragm Case Cap Screw, 

 

  Plated steel (12 required)  

1B596124052

  22   Hex Nut, Zinc-plated steel (12 required)  

1A309324122

  23   Spring Case

 

  Cast iron  

2B155719042

 

  Steel  

34B2157X012

 

  Stainless steel  

34B2157X022

  24   Diaphragm Plate

 

  Up to 1.25 psig / 0.09 bar setpoint  

0B006628982

 

  Over 1.25 psig / 0.09 bar setpoint  

1A347825022

Содержание Y696

Страница 1: ...rnal registration requiring no downstream control line It is used to sense increase in vessel pressure and vent excessive internal vessel pressure to an appropriate vapor recovery disposal or reclamations system Principle of Operation The Type Y696 is used to maintain a constant inlet blanket pressure with the outlet flowing to a system whose pressure is lower than that at the inlet When vessel pr...

Страница 2: ...tions section lists maximum pressures temperatures and other specifications Specifications for a given regulator as it originally comes from the factory are stamped on the spring case nameplate Body Size and End Connection Style 1 See Table 1 Maximum Allowable Inlet and Outlet Pressure 2 15 psig 1 0 bar Control Pressure Ranges See Table 2 Pressure Registration Internal or External Spring Case and ...

Страница 3: ...material Apply pipe compound only to the male pipe threads 2 Install the regulator using a straight run of pipe the same size or larger as the regulator body as shown in Figure 2 Flow through the regulator body is indicated by the flow arrow cast on the body If a block valve is required install a full flow valve between the regulator and the blanketed vessel For proper operation the regulator shou...

Страница 4: ...ge of allowable pressure settings is stamped on the spring casing nameplate If a pressure setting beyond the stamped range is required install a spring with the desired range by following the procedures for changing the spring and diaphragm in the Maintenance section To adjust the pressure setting perform the following steps key numbers are referenced in Figure 3 1 Remove the closing cap key 3 2 T...

Страница 5: ...s to the control spring diaphragm and lever assembly stem All pressure must be released from the diaphragm case assembly before the following steps can be performed To Change the Control Spring 1 Remove the closing cap key 3 and turn the adjusting screw key 2 counterclockwise until all compression is removed from the control spring key 1 2 Remove the adjusting screw key 2 and the upper spring seat...

Страница 6: ...pertinent information stamped on the nameplate Specify the complete 11 character part number from the following parts list when ordering replacement parts Parts List In this parts list parts marked NACE are intended for corrosion resistant service as detailed in the NACE International Standards MR0175 and MR0103 Type Y696 Regulator Figure 3 Key Description Part Number 1 Control Spring Plated steel...

Страница 7: ...Type Y696 7 Figure 3 Type Y696 Assembly Section A A 43B0679 29 50 51 56 75 21 22 6 7 8 9 20 13 11 19 17 16 28 27 47 46 14 41 40 5 24 4 3 2 35 1 30 23 25 38 A A ...

Страница 8: ...res 28008 France Tel 33 2 37 33 47 00 Middle East and Africa Dubai United Arab Emirates Tel 971 4811 8100 TESCOM Emerson Process Management Tescom Corporation USA Headquarters Elk River Minnesota 55330 2445 USA Tels 1 763 241 3238 1 800 447 1250 Europe Selmsdorf 23923 Germany Tel 49 38823 31 287 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9499 For further information visit www fisherregulato...

Отзывы: