44 • XM679K I&O Manual
026-1218 Rev 4
ASr
1.0
Pr2
Differential for fan / offset for anti sweat
heater
[-45°F to 45°F]
[-25.5°C to 25.5°C]
PbA
5.0
Pr2
Proportional band for modulating output
[1°F to 45°F]
[0.1°C to 25.5°C]
AMi
0
Pr2
Minimum output for modulating output
0 to AMA
AMA
100
Pr2
Maximum output for modulating output
AMi to 100
AMt
200
Pr2
Time with fan at maximum speed
0 to 255 s
ALARM
rAL
P1
Pr1
Probe for temperature alarm
nP(0) - P1(1) - P2(2) - P3(3) - P4(4) -
P5(5) - tEr(6)
ALC
Ab
Pr1
Temperature alarm configuration
rE(0) - Ab(1)
ALU
10
Pr1
High temperature alarm setting
[0°F to 90°F or ALL to 302°F]
[0.0°C to 50.0°C or ALL to 150.0°C]
ALL
-30
Pr1
Low temperature alarm setting
[0°F to 90°F or -67°F to ALU°F]
[0.0°C to 50.0°C or -55.0°C to ALU]
AHy
1.0
Pr1
Differential for temperature alarm
[1°F to 45°F]
[0.1°C to 25.5°C]
ALd
15
Pr1
Temperature alarm delay
0 to 255 (min.)
dLU
150
Pr2
High temperature alarm setting
(defrost probe)
[0°F to 90°F or dLL to 302°F]
[0.0°C to 50.0°C or dLL to 150.0°C]
dLL
-55
Pr2
Low temperature alarm setting
(defrost probe)
[0°F to 90°F or -67°F to dLU°F]
[0.0°C to 50.0°C or -55.0°C to dLU]
dAH
1.0
Pr2
Differential for temperature alarm
(defrost probe)
[1°F to 45°F]
[0.1°C to 25.5°C]
ddA
15
Pr2
Temperature alarm delay (defrost probe)
0 to 255 (min.)
FLU
150
Pr2
High temperature alarm setting
(fan probe)
[0°F to 90°F or FLL to 302°F]
[0.0°C to 50.0°C or FLL to 150.0°C]
FLL
-55
Pr2
Low temperature alarm setting
(fan probe)
[0°F to 90°F or -67°F to FLU°F]
[0.0°C to 50.0°C or -55.0°C to FLU]
FAH
1.0
Pr2
Differential for temperature alarm
(fan probe)
[1°F to 45°F]
[0.1°C to 25.5°C]
FAd
15
Pr2
Temperature alarm delay (fan probe)
0 to 255 (min.)
dAo
1.3
Pr1
Delay of temperature alarm at start-up
0 to 24.0(144)(hours.10min)
EdA
30
Pr1
Alarm delay at the end of defrost
0 to 255 min
dot
15
Pr1
Temperature alarm exclusion after door
open
0 to 255 min
Sti
nu
Pr2
Stop regulation interval
“nu”(0) to 24.0(144)(hour.10min)
Std
3
Pr2
Stop duration
1 to 255 min
oA6
AUS
Pr2
Sixth relay output configuration
CPr(0) - dEF(1) - FAn(2) - ALr(3) -
LiG(4) - AUS(5) - db(6) - OnF(7)
oA7
ALr
Pr2
Modulating output configuration
(if CoM=oA7)
CPr(0) - dEF(1) - FAn(2) - ALr(3) -
LiG(4) - AUS(5) - db(6) - OnF(7)
CoM
Cur
Pr2
Modulating output configuration
CUr(0) - tEn(1) - PM5(2) - PM6(3) -
oA7(4)
AOP
cL
Pr1
Alarm relay polarity
OP(0) - CL(1)
iAU
n
Pr1
Auxiliary output independent from ON/
OFF state
n(0) – Y(1)
Table 23-1 - Default Setting Values (Continued)