Symptom

Possible Cause

Corrective Action

Heat, Cool or Fan Runs Constantly.

Possible short in wiring.

1. 

Possible short in thermostat.

2. 

Possible short in heat/cool/fan system.

3. 

FAN Switch set to Fan ON.

4. 

Check each wire connection to  verify they are not                                                                
shorted or touching together. No bare wire should 
stick out from under terminal screws. Try resetting 
the thermostat as described above. If the condition  
persists the manufacturer of your system or 
service person can instruct you on how to test 
the Heat/Cool system for correct operation. If the 
system operates correctly, replace the thermostat. 

Furnace Cycles Too Fast or Too Slow
(narrow or wide temperature swing)

The location of the thermostat and/or the size of 

1. 

the Heating System may be  
influencing the cycle rate.

Digital thermostats normally provide precise  
temperature control and may cycle faster than 
some older mechanical models. A faster cycle rate 
means  the unit turns on and off more frequently 
but runs for a shorter time so there is no increase 
in energy use. If you would like to increase the 
cycle time, clip Jumper W-905 as mentioned in the 
instructions for Hydronic Heating Systems. It is not 
possible to shorten the cycle time. If an accept-
able cycle rate is not achieved as received or by 
clipping W-905 contact a local service person for 
additional suggestions.

Cooling Cycles Too Fast or Too Slow  
(narrow or wide temperature swing)

The location of the thermostat and the size of 

1. 

the Cooling System can influence the cycle rate. 

The cycle rate for cooling is fixed and can not be 
adjusted. Contact a local service person for sug-
gestions.   

Thermostat Setting and Thermostat  
Thermometer Disagree

Thermostat thermometer setting requires adjust-

1. 

ment.  

The thermometer can be ad/- 3 degrees. 
See Temperature Display Adjustment in the 
Operation section.

Blank Display and/or Keypad 
Not Responding

Voltage spike or static discharge.

1. 

Battery change required.

2. 

Replace batteries and check heat/cool system

 

for proper operation. If a voltage spike occurs use  
the Reset Operation listed above.

7

  TROUBLESHOOTING              

CONTINUED FROM FIFTH PAGE

Содержание White-Rodgers 1E78

Страница 1: ...ical power to the system at the main fuse or circuit breaker until installation is complete PART NO 37 6599B Replaces 37 6599A 1026 Failure to follow and read all instructions carefully before installing or operating this control could cause personal injury and or property damage Assemble tools required as shown below WIRE CUTTER STRIPPER Base Back of Thermostat Body RC G RH Y O B W W904 W905 Moun...

Страница 2: ... thermostat to operate properly with your system Thefactorydefaultsettingisforcedairheat ClippingjumperW905on the circuit board will produce a longer heating cycle which is normally for hot water or steam hydronic systems Both settings produce a very accurate temperature control and can be set to your personal preference As received the thermostat cycles the system just under 1 F With W905 clipped...

Страница 3: ...re 7 Typical wiring diagram for heat pump with reversing valve energized in HEAT TRANSFORMER Reversing Valve RC O B JUMPER WIRE Compressor Contactor JUMPER WIRE Reversing valve is energized when the system switch is in the HEAT position Fan Relay If at any time during testing your system does not operate properly contact a qualified service person Fan Operation If your system does not have a G ter...

Страница 4: ...ture F C CONVERTIBILITY The factory default setting is Fahr enheit Clipping W904 jumper on the circuit board see fig 1 will alter this feature to Celsius temperature setting LOW BATTERY INDICATOR If the 2 AAA alkaline batteries are low and should be replaced the display will be blank except for When the batteries are low pressing any but ton will cause the display to operate for ten seconds After ...

Страница 5: ...ion to thermostat or system 3 Furnace Lock Out Condition Heat may also be 4 intermittent 5 Heating system requires service or thermostat requires replacement Re light pilot Set SYSTEM Switch to HEAT and raise setpoint temperature above room temperature Verify thermostat and system wires are securely attached Many furnaces have safety devices that shut down when a lock out condition occurs If the h...

Страница 6: ... off more frequently but runs for a shorter time so there is no increase in energy use If you would like to increase the cycle time clip Jumper W 905 as mentioned in the instructions for Hydronic Heating Systems It is not possible to shorten the cycle time If an accept able cycle rate is not achieved as received or by clipping W 905 contact a local service person for additional suggestions Cooling...

Страница 7: ...www white rodgers com NOTES ...

Страница 8: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Отзывы: