Before you begin using your thermostat, you should be familiar with 
its features and with the display and the location and operation of 
the thermostat buttons. Your thermostat consists of two parts: the 
thermostat body and the base. To remove the body, gently pull it 
straight out from the base. To replace the body, line up the body with 
the base and press gently until the body snaps onto the base.

The Thermostat Buttons and Switches

1   (Up arrow) Raises temperature setting.
2   (Down arrow) Lowers temperature setting.
3   FAN switch (ONAUTO).
4   SYSTEM switch (COOLOFFHEAT).

The Display

5    is displayed when the SYSTEM switch is in the HEAT posi-

tion. 

 is displayed (non-flashing) when the SYSTEM switch 

is in the 

COOL position. 

 is displayed (flashing) when the 

compressor is in lockout mode.

6   Displays current temperature.
7  

 is displayed when the 2 “AAA” batteries are low 

and should be replaced. Nothing else will be displayed. Earlier 
models display 

“LO BATTERY”. Refer to 37-7006.

8   Displays  currently  set  temperature  (this  is  blank  when  

SYSTEM switch is in the 

OFF position).

Operating Features

Now that you are familiar with the thermostat buttons and display, 
read the following information to learn about the many features of 
the thermostat.

• 

SIMULTANEOUS HEATING/COOLING SETPOINT STORAGE 
— You can enter both your heating and cooling setpoints at the 
same time. There is no need to re-enter the thermostat at the 
beginning of each season.

• 

TEMPERATURE  SETTING  —  Press 

  or 

  until  the 

display shows the temperature you want. The thermostat will 
keep the room temperature at the selected temperature.

• 

°F/°C CONVERTIBILITY — The factory default setting is Fahr-
enheit. Clipping W904 jumper on the circuit board (see fig. 1) 
will alter this feature to Celsius temperature setting.

• 

LOW BATTERY INDICATOR — If the 2 “AAA” alkaline batteries 
are low and should be replaced, the display will be blank except 
for 

. When the batteries are low, pressing any but-

ton will cause the display to operate for ten seconds. After ten 
seconds, the display will be blank except for 

. After 

 has been displayed for 4 weeks, the thermostat 

will  raise  the  temperature  10°  above  your  setpoint  in 

COOL 

mode  and  drop  the  temperature  10°  below  your  setpoint  in 
HEAT mode. You cannot program with low batteries, but you 
can override setpoint temperature.

• 

TEMPERATURE DISPLAY ADJUSTMENT — Your new ther-
mostat has been accurately set in our factory. However, if you 
wish, you may adjust your new thermostat temperature display 
to match your old thermostat. This can be accomplished (within 
a ±3° range) as follows:

1.  Press 

 and 

 at the same time for two seconds with 

the SYSTEM switch in 

OFF position.

2.  Press 

 or 

 to adjust the displayed temperature to 

your desired setting.

3.  Move SYSTEM switch from 

OFF to exit the feature.

• 

DISPLAY BACKLIGHT— The display backlight improves dis-
play contrast in low lighting conditions. Selecting backlight ON 
will turn the light on for a short period of time after any button 
is pressed. Selecting backlight OFF (default) will keep the light 
off. Turn the display backlight feature ON as follows:

1.  Press 

  and 

  at  the  same  time  for  two  seconds 

with the SYSTEM switch in HEAT  position. The display will 
alternately show “-L” AND “FF” (off).

2.  Press 

 or 

 to change “FF” to “ON”.

3.  Move SYSTEM switch to OFF to exit the feature.

Figure 8. Thermostat display, buttons and switches

5

  CHECK THERMOSTAT OPERATION 

CONTINUED FROM THIRD PAGE

Содержание White-Rodgers 1E78

Страница 1: ...ical power to the system at the main fuse or circuit breaker until installation is complete PART NO 37 6599B Replaces 37 6599A 1026 Failure to follow and read all instructions carefully before installing or operating this control could cause personal injury and or property damage Assemble tools required as shown below WIRE CUTTER STRIPPER Base Back of Thermostat Body RC G RH Y O B W W904 W905 Moun...

Страница 2: ... thermostat to operate properly with your system Thefactorydefaultsettingisforcedairheat ClippingjumperW905on the circuit board will produce a longer heating cycle which is normally for hot water or steam hydronic systems Both settings produce a very accurate temperature control and can be set to your personal preference As received the thermostat cycles the system just under 1 F With W905 clipped...

Страница 3: ...re 7 Typical wiring diagram for heat pump with reversing valve energized in HEAT TRANSFORMER Reversing Valve RC O B JUMPER WIRE Compressor Contactor JUMPER WIRE Reversing valve is energized when the system switch is in the HEAT position Fan Relay If at any time during testing your system does not operate properly contact a qualified service person Fan Operation If your system does not have a G ter...

Страница 4: ...ture F C CONVERTIBILITY The factory default setting is Fahr enheit Clipping W904 jumper on the circuit board see fig 1 will alter this feature to Celsius temperature setting LOW BATTERY INDICATOR If the 2 AAA alkaline batteries are low and should be replaced the display will be blank except for When the batteries are low pressing any but ton will cause the display to operate for ten seconds After ...

Страница 5: ...ion to thermostat or system 3 Furnace Lock Out Condition Heat may also be 4 intermittent 5 Heating system requires service or thermostat requires replacement Re light pilot Set SYSTEM Switch to HEAT and raise setpoint temperature above room temperature Verify thermostat and system wires are securely attached Many furnaces have safety devices that shut down when a lock out condition occurs If the h...

Страница 6: ... off more frequently but runs for a shorter time so there is no increase in energy use If you would like to increase the cycle time clip Jumper W 905 as mentioned in the instructions for Hydronic Heating Systems It is not possible to shorten the cycle time If an accept able cycle rate is not achieved as received or by clipping W 905 contact a local service person for additional suggestions Cooling...

Страница 7: ...www white rodgers com NOTES ...

Страница 8: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Отзывы: