background image

4

Technical specifications

Specifications

Operating distance

1

Up to 30 ft (9 m) without reflective tape
Up to 100 ft (30 m) with reflective tape

Laser class

FDA Class IIIa, < 5mw, 650 nm, IEC Class 3B (International)

Temperature range

15°-120° F (-10° - 50° C)

Accuracy

+/- 0.05%

Resolution

5-digit display

Dynamic range

2 to 120,000+ RPM

Input voltage

5.0 - 7.2 VDC (supplied by analyzer)

Output voltage

+/- 2.5 VDC Analog

Input current

58 mA

Weight

0.43 lbs.

Compliance

FDA, IEC, CE

1

Tripod or other mounting may be required to achieve longer operating

distances.

User Guide

August 2018

24

Содержание SpeedVue 430

Страница 1: ...User Guide MHM 97020 Rev 11 August 2018 Emerson 430 SpeedVue Laser Speed Sensor User Guide ...

Страница 2: ...User Guide August 2018 2 ...

Страница 3: ...ED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Emerson shall not be liable for errors omissions or inconsistencies that may be contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Information in this document is subject to change without notice and does not represent a commitment on the part of Emer...

Страница 4: ...ntents Emerson 430 SpeedVue overview 5 Install the Emerson 430 SpeedVue 13 Use the Emerson 430 SpeedVue with the AMS 2140 Machinery Health Analyzer 18 Technical specifications 24 User Guide August 2018 4 ...

Страница 5: ... operation The Emerson 430 SpeedVue uses laser light to detect rotational speed without reflective tape Using reflective tape may enhance the return signal but in ideal cases the Emerson 430 SpeedVue does not require any tape or paint marks and may function up to approximately 30 feet away from the equipment The Emerson 430 SpeedVue may also be used to detect belts and pulleys and display the resu...

Страница 6: ...erviceable Please contact the manufacturer for any service or technical support To view toll free numbers for specific countries visit http www emersonprocess com technicalsupport 1 3 Safety Emerson 430 SpeedVue Sensor may not be compatible with the AMS 2140 labeled ATEX IECEx Zone 2 The Emerson 430 is not permitted in hazardous areas and it may not function with the ATEX certified AMS 2140 even i...

Страница 7: ...ry Use of laser protective eyewear is suggested or recommended A Class 3B laser can be a distraction and are a glare or flash blindness hazard for users and coworkers Always be aware of the beam location Keep it away from eyes and heads Watch out for reflected beams from glass and shiny surfaces ONLY ALLOW USE BY TRAINED RESPONSIBLE PERSONS Class 3B Laser eye injury hazards Class 3B visible light ...

Страница 8: ...njury hazards A Class 3B laser is not normally considered a skin or materials burn hazard However if the laser dot is kept motionless on skin at close range heat can be felt The more powerful the Class 3B laser the sooner the heat will build up Do not deliberately attempt to burn skin This can be very painful can take a long time to heal and can leave a permanent scar Class 3B Laser protective eye...

Страница 9: ...ardous exposures Markings The Emerson 430 has a laser radiation label that warns users to avoid exposure to the laser beam Laser warning icon Figure 1 1 1 5 Standard equipment Depending on what package is ordered in addition to the Emerson 430 SpeedVue it may include a signal power cable storage case this user manual and a sensor holder for the AMS 2140 August 2018 User Guide 9 ...

Страница 10: ...n 430 SpeedVue side view with labels Side view with example labels Figure 1 2 A Laser aperture B Beam attenuator C Laser label D Mounting hole 3 8 24 thread E Identification and CE label User Guide August 2018 10 ...

Страница 11: ...n the red marks and push the plug straight into the receptacle WARNING Only trained personnel should have access to the Emerson 430 and cable The provided cable functions as a key Without the proper installation of the cable to the AMS 2140 and the Emerson 430 power will not be provided to the Emerson 430 When the Emerson 430 is not in use the Emerson 430 and the cable should be disconnected from ...

Страница 12: ...gerprints and smudges by moistening cotton swabs and or optical tissue with isopropyl alcohol and carefully wiping the optical window To avoid scratching the window ensure all loose dirt and grit are removed by the blower brush before wet cleaning Note Keep the beam attenuator dust cap closed when the Emerson 430 SpeedVue is not in use WARNING Do not attempt to clean the optical window if the lase...

Страница 13: ... Do not use any abrasive or corrosive chemicals or materials Do not use petroleum distillates and ketone solvents for example acetone gasoline and kerosene Use a dry lint free towel or cloth dampened with a mild soap and water solution 3 8 24 thread mount On the side of the Emerson 430 SpeedVue is a 3 8 24 threaded hole for use with Emerson s Magnetic Swivel Base B404 BASE The Magnetic Swivel Base...

Страница 14: ...to the AMS 2140 Use the shoulder strap connectors on either side of the analyzer to attach the sensor holder You can use the shoulder strap while the Emerson 430 SpeedVue is mounted onto the AMS 2140 Procedure 1 To use the AMS 2140 shoulder strap with the Emerson 430 sensor holder rotate out the shoulder strap connector on the inside of the sensor holder The sensor holder has two shoulder strap co...

Страница 15: ...he sides of the sensor holder and insert the holder into the connectors on either side of the AMS 2140 3 Release the buttons to secure the sensor holder 4 Slide the Emerson 430 SpeedVue into the clamp on the sensor holder until secure Rotate the clamp 360 degrees to set the Emerson 430 SpeedVue laser beam in the desired position August 2018 User Guide 15 ...

Страница 16: ...Vue mounted onto the AMS 2140 Figure 2 2 5 To remove the sensor holder from the AMS 2140 press and hold the two buttons on the sensor holder and then pull to remove the holder from the analyzer User Guide August 2018 16 ...

Страница 17: ...e ON position Also the Tach Power setting must be turned on in the AMS 2140 Machinery Health Analyzer Tachometer Setup screen See the AMS 2140 Machinery Health Analyzer User Guide for more information See Section 3 5 for more information about how to automatically turn off the Emerson 430 SpeedVue after a measurement Procedure 1 Connect the analyzer and the Emerson 430 SpeedVue using the power cab...

Страница 18: ...merson 430 SpeedVue after a measurement 3 1 Detect the machine speed for non route equipment 1 From the analyzer Home screen press F7 Analyze 2 Press F12 Laser Speed Detection on the Analyze main menu to activate the Emerson 430 SpeedVue Analyze main menu Figure 3 1 A help message appears to guide you through each step 3 Press Start 4 Use the up and down arrow keys to select the speed range and pr...

Страница 19: ...he new peak F4 Full Screen View a full screen version of the plot F6 Switch Plot Type Select a spectrum or waveform plot F8 Start Select an estimated speed range and begin the measurement F10 Cursor Mark Mark a frequency and display the speed at that point on the screen F11 Expand X Axis Expand the axis on the data plot F12 Compress X Axis Compress the axis on the data plot 3 3 Detect turning spee...

Страница 20: ...peed range and press Enter Note The speed range menu from Route defaults to the measurement point speed range 6 Press Enter to view the data The detected speed is automatically marked on the spectrum and displayed at the bottom of the screen The correct speed transfers to the Route Data Collection screen User Guide August 2018 20 ...

Страница 21: ...ng speed for equipment set up for RPM 1 From the analyzer Home screen press F8 Route 2 Activate a route 3 From the Route Data Collection screen press F12 Laser Speed Detection Route Data Collection screen Figure 3 5 The Laser Speed Detection screen appears 4 Use the up and down arrow keys to select the speed range and press Enter August 2018 User Guide 21 ...

Страница 22: ...t RPM if the speed is correct The correct speed displays on the Route Data Collection screen 7 Press Enter to collect normal vibration data 3 5 Automatically turn off the Emerson 430 SpeedVue after a measurement 1 From the Route Data Collection screen press ALT F5 Tach Setup The Tachometer Setup screen appears User Guide August 2018 22 ...

Страница 23: ...e switch is turned On the laser beam stays on continuously Tach Power OFF If the Emerson 430 SpeedVue switch is turned On the Emerson 430 automatically turns power on for the speed measurement and turns off after the measurement finishes Note Emerson recommends leaving the F5 Tach Power set to Off to conserve battery power August 2018 User Guide 23 ...

Страница 24: ...nm IEC Class 3B International Temperature range 15 120 F 10 50 C Accuracy 0 05 Resolution 5 digit display Dynamic range 2 to 120 000 RPM Input voltage 5 0 7 2 VDC supplied by analyzer Output voltage 2 5 VDC Analog Input current 58 mA Weight 0 43 lbs Compliance FDA IEC CE 1Tripod or other mounting may be required to achieve longer operating distances User Guide August 2018 24 ...

Страница 25: ...ob mode 18 L labels 10 laser class 24 Class 3B IIIb 7 9 safety 6 LEMO connector 11 M magnetic mount 13 14 mounting methods AMS 2140 13 14 magnetic mount 13 14 O operating distance 24 output voltage 24 P plot options 19 power on indicator 11 power on off switch 11 power the Emerson 430 17 R resolution 24 Route program 19 21 RPM 21 S Set Divisor 19 Set RPM 19 signal power connector 11 specifications...

Страница 26: ...technical specifications 24 technical support 6 temperature range 24 tripod mounting 13 14 W weight 24 User Guide August 2018 26 ...

Страница 27: ...ey are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which are available on request We reserve the right to modify or improve the designs or specifications of our products at any time without notice All rights reserved The Emerson logo is a trade...

Отзывы: