SI-PROFINET RT User Guide
29
Issue Number: 2
Saf
ety
In
M
El
G
A
Pa
ra
D
G
Changes to the module's configuration will not take effect until the module has been
reset.
To reset the module:
•
Set Pr
S.00.007
to On (1).
•
When the sequence has been completed, Pr
S.00.007
will be reset to Off (0).
•
The module will reset using the updated configuration.
This sequence does NOT store the module's configuration parameters in the drive or
the module's flash memory. This parameter will change back to Off immediately, and as
such the change may not be visible in the display.
If the host drive is defaulted (see the drive user guide for details), it will also clear the
current configuration for the slot the module is installed to.
This can be performed as follows:
•
Set Pr
S.00.008
to On.
•
Reset the module by setting Pr
S.00.007
to On.
•
Default parameter values for the module will be loaded.
The module will reset using the default values.
This parameter displays the number of the virtual option slot on the drive that the
module is connected to.
S.00.007
Reset Module
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
Read every 200 ms
Display Format
None
Decimal Places
0
Coding
RW, NC
S.00.008
Default Module
Minimum
0
Maximum
1
Default
0
Units
Type
1 Bit Volatile
Update Rate
Read on module
reset
Display Format
None
Decimal Places
0
Coding
RW, NC
S.00.030
Slot Indicator
Minimum
0
Maximum
8
Default
Units
Type
8 Bit Volatile
Update Rate
Written on power-
up
Display Format
None
Decimal Places
0
Coding
RO, ND, PT
NOTE