Menus
The table below details each of the module's internal menus.
S is the slot number where the module is installed.
The module's menu 0 is also displayed in menu 15, 16 or 17 depending on which slot
the module in installed in. The table below shows the location of the module's menu 0
on the drive.
Menu 0 - Module Set-up
All parameters in
S.00.ppp
(i.e. menu 0 within the option module menus) are also
present in menus 15, 16 or 17 depending on the slot that the module is installed to e.g.
Pr
3.00.007
is also present as 17.007.
The functionality and properties of the parameters are identical between the two menus.
Pr
S.00.001
displays the ID number for the Option Module. For SI-PROFINET RT, this is
432.
The firmware version of the option module is in the format of
ww.xx.yy.zz
Menu
Description
S.00
Module information
S.02
PROFINET Ethernet Configuration
S.05
PROFINET Configuration
Slot number
Menu 0 location
1
15
2
16
3
17
S.00.001
Module ID
Minimum
0
Maximum
65535
Default
432
Units
Type
16 Bit Volatile
Update Rate
Power-up write
Display Format
None
Decimal Places
0
Coding
RO, ND, NC, PT, BU
S.00.002
Firmware version
Minimum
0 (Display 00.00.00.00) Maximum
99999999 (Display
99.99.99.99)
Default
Units
Type
32 Bit Volatile
Update Rate
Power-up write
Display Format
Version Number
Decimal Places
0
Coding
RO, ND, NC, PT