30
Reference Manual
00809-0100-4021, Rev GC
Section 3: HART commissioning
April 2014
3.3
Safety messages
Instructions and procedures in this section may require special precautions to ensure the safety
of the personnel performing the operations. Information that raises potential safety issues is
indicated by a warning symbol ( ). Please refer to the following safety messages before
performing an operation preceded by this symbol.
3.4
Field communicator
The Menu Tree and Fast Key sequences use the following device revisions:
Device Dashboard: Device Revision 5 and 6, DD v1
The field communicator exchanges information with the transmitter from the control room, the
instrument site, or any wiring termination point in the loop. To facilitate communication,
connect the field communicator in parallel with the transmitter (see
) using the loop
connection ports on the top of the field communicator. The connections are non-polarized. Do
not make connections to the NiCad recharger jack in explosive atmospheres. Before connecting
the field communicator in an explosive atmosphere, make sure the instruments in the loop are
installed according to intrinsically safe or non-incendive field wiring practices
3.4.1
Updating the HART communication software
The field communicator software may need to be updated to take advantage of the additional
features available in the latest 3144P. Perform the following steps to determine if an upgrade is
necessary.
1.
Choose “Rosemount” from the list of manufacturers 5 and 6 and “3144 Temp” from the
list of models.
2.
If the Field Device Rev choices include “Dev v1,” “Dev v2,” “Dev v3,” or “Dev v4” (with
any DD version), then the user will be able to connect to the device with reduced
functionality. To unlock full functionality, download and install the new DD.
Note
The original release of the safety-certified 3144P uses the name “3144P SIS” from the model list
and requires “Dev v2, DD v1.”
Explosions may result in death or serious injury.
Do not remove the instrument cover in explosive atmospheres when the circuit is live.
Before connecting a Field Communicator in an explosive atmosphere, make sure the
instruments in the loop are installed in accordance with intrinsically safe or
non-incendive field wiring practices.
Both covers must be fully engaged to meet explosion–proof requirements.
Electrical shock could cause death or serious injury. If the sensor is installed in a
high-voltage environment and a fault or installation error occurs, high voltage may be
present on transmitter leads and terminals.
Use extreme caution when making contact with the leads and terminals.
Содержание Rosemount
Страница 1: ...Reference Manual 00809 0100 4021 Rev GC April 2014 Rosemount 3144P Temperature Transmitter ...
Страница 2: ......
Страница 4: ...iv Reference Manual 00809 0100 4021 Rev GC Title Page April 2014 ...
Страница 10: ...x Reference Manual 00809 0100 4021 Rev GC Table of Contents April 2014 Table of Contents ...
Страница 38: ...28 Reference Manual 00809 0100 4021 Rev GC Section 2 Installation April 2014 Installation ...
Страница 188: ...178 Reference Manual 00809 0100 4021 Rev GC Section 5 Maintenance April 2014 Maintenance ...
Страница 233: ...227 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 234: ...228 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 235: ...229 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 237: ...231 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 238: ...232 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 244: ...238 Reference Manual 00809 0100 4021 Rev GC Appendix B Product Certifications April 2014 Product Certifications ...
Страница 250: ...Index 244 Reference Manual 00809 0100 4021 Rev GC Index April 2014 Index ...
Страница 251: ......