background image

Safety and approval information

This Rosemount product complies with all applicable European directives when properly installed in accordance with the
instructions in this manual. Refer to the EU declaration of conformity for directives that apply to this product. The EU declaration
of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available
on the internet at 

www.emerson.com

 or through your local Emerson support center.

Information affixed to equipment that complies with the Pressure Equipment Directive, can be found on the internet at 

http://

www.emerson.com

.

For hazardous installations in Europe, refer to standard EN 60079-14 if national standards do not apply.

Other information

Full product specifications can be found in the product data sheet. Troubleshooting information can be found in the user manual.
Product data sheets and manuals are available from the Emerson website at 

http://www.emerson.com

.

Return policy

Follow Emerson procedures when returning equipment. These procedures ensure legal compliance with government
transportation agencies and help provide a safe working environment for Emerson employees. Emerson will not accept your
returned equipment if you fail to follow Emerson procedures. Return procedures and forms are available on our web support site
at 

Emerson.com

, or by phoning the Emerson Customer Service department.

Emerson Flow customer service

Email:

Worldwide: 

http://[email protected]

Asia-Pacific: 

http://[email protected]

Telephone:

North and South America

Europe and Middle East

Asia Pacific

United States

800 522 6277

U.K.

0870 240 1978

Australia

800 158 727

Canada

+1 303 527 5200

The Nethe31 (0) 704 136 666

New Zealand

099 128 804

Mexico

+41 (0) 41 7686 111

France

0800 917 901

India

800 440 1468

Argentina

+54 11 4837 7000

Germany

0800 182 5347

Pakistan

888 550 2682

Brazil

+55 15 3413 8000

Italy

8008 77334

China

+86 21 2892 9000

Central & E41 (0) 41 7686 111

Japan

+81 3 5769 6803

Russia/CIS

+7 495 981 9811

South Korea

+82 2 3438 4600

Egypt

0800 000 0015

Singapore

+65 6 777 8211

Oman

800 70101

Thailand

001 800 441 6426

Qatar

431 0044

Malaysia

800 814 008

Kuwait

663 299 01

South Africa

800 991 390

Saudi Arabia

800 844 9564

UAE

800 0444 0684

2

Содержание Rosemount Ultrasonic 100 Series

Страница 1: ...Installation Procedure 00809 0100 3105 Rev AA February 2022 Rosemount Ultrasonic Series 100 Option Board Field ...

Страница 2: ...equipment These procedures ensure legal compliance with government transportation agencies and help provide a safe working environment for Emerson employees Emerson will not accept your returned equipment if you fail to follow Emerson procedures Return procedures and forms are available on our web support site at Emerson com or by phoning the Emerson Customer Service department Emerson Flow custom...

Страница 3: ...start 7 Part II Install Chapter 2 Installation of the Option Board 13 2 1 Instructions before opening the unit 13 2 2 Instructions to install the Option Board 13 Appendix A Engineering Drawings 23 Installation Procedure Contents 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 3 ...

Страница 4: ...Contents Installation Procedure February 2022 00809 0100 3105 4 Emerson com Rosemount ...

Страница 5: ...Part I Plan Installation Procedure Plan 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 5 ...

Страница 6: ...Plan Installation Procedure February 2022 00809 0100 3105 6 Emerson com Rosemount ...

Страница 7: ...before taking the Ultrasonic meter out of service 1 2 1 Required parts Series 100 Option Board Field Installation Kit P N 2 9 3400 844 Series 100 Option Board Field Installation Kit w Keys P N 2 9 3400 845 Series 100 Plus HART Option Board Field Installation Kit P N 2 9 3400 855 Series 100 Plus HART Option Board Field Installation Kit w Keys P N 2 9 3400 856 The kits contain the following componen...

Страница 8: ...dard Edition Installation CD 1 Contains upgrade to latest Deluxe Edition of Daniel CUI if Deluxe Edition already installed on computer 1 Contains upgrade to latest Ultrasonic firmware upgrade that supports Series 100 Option Board 4 Feature keys will be supplied by a Customer Service Representative for kits including keys for Ethernet Archive Logs AGA 10 and GC Master 1 2 2 Required tools A 1 8 fla...

Страница 9: ... Ground strap Installation Procedure Introduction 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 9 ...

Страница 10: ...Introduction Installation Procedure February 2022 00809 0100 3105 10 Emerson com Rosemount ...

Страница 11: ...Part II Install Installation Procedure Install 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 11 ...

Страница 12: ...Install Installation Procedure February 2022 00809 0100 3105 12 Emerson com Rosemount ...

Страница 13: ...tronics can result in damage to the equipment 2 2 Instructions to install the Option Board Procedure 1 Before disconnecting unit power to install the option board connect to the meter with Daniel CUI and make sure the meter has the latest version of firmware installed for meter If you install an option board in a meter with firmware that does not support the board the meter will not be able to rec...

Страница 14: ...ter version of firmware is included The firmware for your meter can be found under one of the following directories on the CD Ultrasonic Gas Rosemount Mark III Firmware Ultrasonic Liquid Rosemount 3800 Firmware Use the Program Download utility under the Tools pull down menu in Daniel CUI to upgrade the firmware in the meter if necessary Clicking F1 with the Program Download utility open will displ...

Страница 15: ...e screws Disconnect the cable and remove the CPU board from the enclosure Figure 2 3 Remove CPU board 5 Use a Phillips head screwdriver to remove the washers and screws from the three standoffs attached to the Option board Installation Procedure Installation of the Option Board 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 15 ...

Страница 16: ...Figure 2 4 Prepare Option board Installation of the Option Board Installation Procedure February 2022 00809 0100 3105 16 Emerson com Rosemount ...

Страница 17: ...Figure 2 5 Option Board Connectors Switches LEDs Installation Procedure Installation of the Option Board 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 17 ...

Страница 18: ...ided as a reference 7 Install the Option board on the CPU board making sure that the connector on the bottom of the Option board mates to the connector on top of the CPU board Figure 2 7 Mount Option board 8 Secure the Option board to the CPU board with the three Kep screws Installation of the Option Board Installation Procedure February 2022 00809 0100 3105 18 Emerson com Rosemount ...

Страница 19: ... with the newer revision a Use a hex driver to remove the nut that attaches the Wiring Diagram Card Remove the old card and install the new card provided with the Option Board Kit Secure the card in place with the hex nut Installation Procedure Installation of the Option Board 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 19 ...

Страница 20: ...ining screws Figure 2 10 Attach acquisition cable to CPU board 11 Slide the CPU board back onto the card guides and seat it in the Field Connection board Push the locking mechanism on both card guides to the Locked position as Installation of the Option Board Installation Procedure February 2022 00809 0100 3105 20 Emerson com Rosemount ...

Страница 21: ...the Field Connection board as shown The Series 100 Option board will have plugs fully populating connectors J11 and J12 The Series 100 Plus HART Option board will have plugs fully populating connector J10 J11 and J12 a Install wiring and conduit for the Option board I O Installation Procedure Installation of the Option Board 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Boar...

Страница 22: ...nstall the end caps on each end of the upper electronics enclosure a Reapply power to the unit Figure 2 13 Install end caps Installation of the Option Board Installation Procedure February 2022 00809 0100 3105 22 Emerson com Rosemount ...

Страница 23: ...E 21056 Mark III Ultrasonic System Wiring Ultrasonic Flowmeter Model 3400 3410 and 3420 Sheets 1 3 Installation Procedure Engineering Drawings 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 23 ...

Страница 24: ...Mark III Ultrasonic System Wiring Ultrasonic Flowmeter Model 3400 3410 and 3420 DE 21056 Engineering Drawings Installation Procedure February 2022 00809 0100 3105 24 Emerson com Rosemount ...

Страница 25: ...er Model 3400 3410 and 3420 DE 21056 Mark III Ultrasonic System Wiring Ultrasonic Flowmeter Model 3400 3410 and 3420 DE 21056 Installation Procedure Engineering Drawings 00809 0100 3105 February 2022 Rosemount Ultrasonic Series 100 Option Board Field 25 ...

Страница 26: ... All rights reserved Emerson Terms and Conditions of Sale are available upon request The Emerson logo is a trademark and service mark of Emerson Electric Co Rosemount is a mark of one of the Emerson family of companies All other marks are the property of their respective owners ...

Отзывы: