Supply Wire Requirements
Use 12 to 18 AWG wire rated for the proper temperature of the application. For connections
in ambient temperatures above 140 °F (60 °C), use a wire rated for 176 °F (80 °C). For
ambient temperatures greater than 176 °F (80 °C), use a wire rated for 230 °F (110 °C). For
DC powered transmitters with extended cable lengths, verify that there is a minimum of 12 V
DC at the terminals of the transmitter.
Disconnects
Connect the device through an external disconnect or circuit breaker. Clearly label the
disconnect or circuit breaker and locate it near the transmitter and per local electrical
control.
Installation Category
The installation category for the 8712E / 8732E is (Overvoltage) Category II.
Overcurrent Protection
The Rosemount 8712E / 8732E flowmeter transmitter requires overcurrent protection of the
supply lines. Maximum ratings of overcurrent devices are shown in Table 10.
Table 10. Overcurrent Limits
Power System
Fuse Rating
Manufacturer
95-250 V AC
2 Amp, Quick Acting
Bussman AGC2 or Equivalent
12-42 V DC
3 Amp, Quick Acting
Bussman AGC3 or Equivalent