5
Rosemount 65Q
September 2014
www.rosemount.com
Sensor lead wire termination
0
Flying Leads – No Springs on DIN plate
★
2
Terminal Block – DIN 43762
★
Sensor type
Temperature range
1
RTD, Single Element, 4-wire
– 50 to 450 °C
★
2
RTD, Dual Element, 3-wire
– 50 to 450 °C
★
5
RTD, Single Element, 3-wire
– 50 to 450 °C
★
Extension
S
Tubular with Extension, Welded Screw Bush M24 x 1.5
★
Z
Tubular with Extension, Head Connection Adjustable Loose Screw Nut M24 x 1.5
★
Extension length (N) in millimeters
0050
(2)
50 mm
★
0065
(3)
65 mm
★
0130
130 mm
★
XXXX
Non-standard extension length – non-standard lengths are available from 50 to 990 mm
★
Thermowell material
D
1.4404 (AISI 316L) Stainless Steel,
≤
0.8
μ
m electropolishing
★
Immersion length (L) in millimeters
0025
25 mm – not available for Mounting Style code T02
★
0050
50 mm
★
0065
65 mm
★
0100
100 mm
★
0150
150 mm
★
0200
200 mm
★
0250
250 mm
★
XXXX
Non-standard immersion length – non-standard lengths are available from 25 to 2500 mm
Thermowell mounting style
Process connection
Stem style
C02
Flanged
1-in. Tri-Clamp
™
(diameter 50.4 mm)
Stepped, 10/6 mm
(4)
★
C04
Flanged
1
1
/
2
-in. Tri-Clamp (diameter 50.4 mm)
Stepped, 10/6 mm
(4)
★
C06
Flanged
2-in. Tri-Clamp (diameter 64 mm)
Stepped, 10/6 mm
(4)
★
C08
Flanged
2
1
/
2
-in. Tri-Clamp (diameter 77.4 mm)
Stepped, 10/6 mm
(4)
★
C10
Flanged
3-in. Tri-Clamp (diameter 91 mm)
Stepped, 10/6 mm
(4)
★
C12
Flanged
4-in. Tri-Clamp (diameter 119 mm)
Stepped, 10/6 mm
(4)
★
C14
Flanged
1
/
2
-in. Tri-Clamp (diameter 24.9 mm)
Stepped, 10/6 mm
(4)
★
Table 1. 65Q RTD Assembly (Pt 100) for Hygienic and Food and Beverage Applications
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
__
The Expanded offering is subject to additional delivery lead time.