![Emerson Rosemount 644 FOUNDATION Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/emerson/rosemount-644-foundation/rosemount-644-foundation_reference-manual_104730040.webp)
34
Reference Manual
00809-0400-4728, Rev CA
Installation
September 2018
Installation
3.4.3
LCD display installation
The LCD display provides local indication of the transmitter output and abbreviated diagnostic messages
governing transmitter operation. Transmitters ordered with the LCD display are shipped with the meter
installed. After-market installation of the meter can be performed if the transmitter has a meter
connector (transmitter revision 5.5.2 or later). After-market installation requires the meter kit
(part number 00644-4430-0001), which includes:
LCD display assembly (includes LCD display, meter spacer, and two screws)
Meter cover with O-ring in place
Figure 3-4. Installing the LCD Display
Use the following procedure to install the meter.
1. If the transmitter is installed in a loop, secure the loop and disconnect the power. If the transmitter is
installed in an enclosure, remove the cover from the enclosure.
2. Decide meter orientation (the meter can be rotated in 90° increments). To change meter orientation,
remove the screws located above and below the display screen. Lift the meter off the meter spacer.
Remove the 8-pin plug and re-insert it in the location that will result in the desired viewing
orientation.
3. Reattach the meter to the meter spacer using the screws. If the meter was rotated 90° from its
original position, it will be necessary to remove the screws from their original holes and re-insert
them in the adjacent screw’s holes.
4. Line up the 10-pin connector with the 10-pin socket and push the meter into the transmitter until it
snaps into place.
5. Attach the meter cover; tighten at least one-third turn after the O-ring contacts the transmitter
housing. The cover must be fully engaged to meet explosion-proof requirements.
6. Use a Field Communicator, AMS software, or a F
OUNDATION
Fieldbus Communication tool to configure
the meter to the desired display.
Note
Observe the following LCD display temperature limits:
Operating: –4 to 185 °F (–20 to 85 °C)
Storage: –50 to 185 °F (–45 to 85 °C)
A. LCD display
B. 10-pin connector
C. Meter space
D. Captive mounting screws and springs
E. Rosemount 644H
A
C
B
D
E
Содержание Rosemount 644 FOUNDATION
Страница 2: ......
Страница 6: ...4 Reference Manual 00809 0100 4728 Rev CA Title Page September 2018 Title Page ...
Страница 10: ...4 Reference Manual 00809 0400 4728 Rev CA Introduction September 2018 Introduction ...
Страница 34: ...28 Reference Manual 00809 0400 4728 Rev CA Configuration September 2018 Configuration ...
Страница 48: ...Reference Data September 2018 Reference Manual 00809 0400 4728 Rev CA Reference Data 42 ...
Страница 63: ......