25
Reference Manual
00809-0400-4728, Rev CA
Configuration
September 2018
Configuration
2.5.5
Resource block
This section describes error conditions found in the Resource block. Read
to determine the appropriate corrective action.
Block errors
lists conditions reported in the BLOCK_ERR parameter.
Table 2-6. AI BLOCK_ERR Conditions
Condition
number
Condition name and description
0
Other
1
Block Configuration Error: The selected channel carries a measurement that is incompatible with
the engineering units selected in XD_SCALE, the L_TYPE parameter is not configured, or CHANNEL
= zero.
3
Simulate Active: Simulation is enabled and the block is using a simulated value in its execution.
7
Input Failure/Process Variable has Bad Status: The hardware is bad, or a bad status is being
simulated.
14
Power Up
15
Out of Service: The actual mode is out of service.
Table 2-7. Troubleshooting the AI Block
Symptom
Possible causes
Recommended actions
Bad or no temperature
readings
(Read the AI “BLOCK_ERR”
parameter)
BLOCK_ERR reads OUT OF
SERVICE (OOS)
1. AI Block target mode target mode set to OOS.
2. Resource Block OUT OF SERVICE.
BLOCK_ERR reads
CONFIGURATION ERROR
1. Check CHANNEL parameter (see
)
2. Check L_TYPE parameter (see
)
3. Check XD_SCALE engineering units. (see
BLOCK_ERR reads POWERUP
Download Schedule into block. Refer to host for downloading
procedure.
BLOCK_ERR reads BAD INPUT
1. Sensor Transducer Block Out Of Service (OOS)
2. Resource Block Out of Service (OOS)
No BLOCK_ERR but readings
are not correct. If using
Indirect mode, scaling could
be wrong.
1. Check XD_SCALE parameter.
2. Check OUT_SCALE parameter.
“XD_SCALE and OUT_SCALE” on page 14
No BLOCK_ERR. Sensor needs
to be calibrated or Zero
trimmed.
to determine the appropriate
trimming or calibration procedure.
OUT parameter status reads
UNCERTAIN and substatus
reads EngUnitRangViolation.
Out_ScaleEU_0 and EU_100
settings are incorrect.
Содержание Rosemount 644 FOUNDATION
Страница 2: ......
Страница 6: ...4 Reference Manual 00809 0100 4728 Rev CA Title Page September 2018 Title Page ...
Страница 10: ...4 Reference Manual 00809 0400 4728 Rev CA Introduction September 2018 Introduction ...
Страница 34: ...28 Reference Manual 00809 0400 4728 Rev CA Configuration September 2018 Configuration ...
Страница 48: ...Reference Data September 2018 Reference Manual 00809 0400 4728 Rev CA Reference Data 42 ...
Страница 63: ......