background image

Manual Supplement

00809-0200-4108, Rev AB

December 2018

Global Headquarters

Emerson Automation Solutions

6021 Innovation Blvd.
Shakopee, MN 55379, USA

+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001 
[email protected]

North America Regional Office

Emerson Automation Solutions 

8200 Market Blvd.
Chanhassen, MN 55317, USA

+1 800 999 9307 or +1 952 906 8888
+1 952 949 7001                                                                       
[email protected]

Latin America Regional Office

Emerson Automation Solutions 

1300 Concord Terrace, Suite 400
Sunrise, FL 33323, USA 

+1 954 846 5030
+1 954 846 5121
[email protected]

Europe Regional Office

Emerson Automation Solutions Europe GmbH

Neuhofstrasse 19a P.O. Box 1046
CH 6340 Baar
Switzerland

+41 (0) 41 768 6111
+41 (0) 41 768 6300 
[email protected]

Asia Pacific Regional Office

Emerson Automation Solutions 

1 Pandan Crescent
Singapore 128461

+65 6777 8211
+65 6777 0947 
[email protected]

Middle East and Africa Regional Office

Emerson Automation Solutions 

Emerson FZE P.O. Box 17033
Jebel Ali Free Zone - South 2
Dubai, United Arab Emirates

+971 4 8118100
+971 4 8865465 
[email protected]

Linkedin.com/company/Emerson-Automation-Solutions

Twitter.com/Rosemount_News

Facebook.com/Rosemount

Youtube.com/user/RosemountMeasurement

Google.com/+RosemountMeasurement

Emerson Terms and Conditions of Sale are available upon request.

The Emerson logo is a trademark and service mark of Emerson Electric Co.

Rosemount and Rosemount logotype are trademarks of Emerson.
All other marks are the property of their respective owners.

©

 2018 Emerson. All rights reserved.

Содержание Rosemount 2090

Страница 1: ...re installing into SIS systems To identify a safety certified Rosemount 2090 1 Check Namur Software Revision located on the metal device tag SW _ _ _ Namur Software Revision Number SW 1 1 0 x 1 4 x 1 NAMUR Software Revision Located on the metal device tag 2 Verify that option code QT is included in the transmitter model code 1 2 Installation in SIS applications Installations are to be performed by...

Страница 2: ...will affect the transmitters ability to respond to changes in the applied process The damping value response time must not exceed the loop requirements See the Reference Manual 1 5 Alarm and saturation levels DCS or safety logic solver should be configured to match transmitter configuration Figure 1 1 identifies the three alarm levels available and their operation values Figure 1 1 Alarm levels 1 ...

Страница 3: ...ent of possible DU failures in the device FMEDA report can be found at Emerson com Rosemount Safety Products Required tools Field Communicator and mA meter 1 Bypass the safety function and take appropriate action to avoid a false trip 2 Use HART Communications to retrieve any diagnostics and take appropriate action 3 Send a HART command to the transmitter to go to the high alarm current output and...

Страница 4: ...ures 2 This tests for compliance voltage problems such as a low loop power supply voltage or increased wiring distance This also tests for other possible failures Note The user determines the proof test requirements for impulse piping Automatic diagnostics are defined for the corrected percent DU The tests performed internally by the device during runtime without requiring enabling or programming ...

Страница 5: ...at Emerson com Rosemount Safety Products 3 4 Failure values Transmitter response time Reference Appendix A specifications and reference data in the Reference Manual Self diagnostics test interval At least once every 60 minutes 3 5 Product life 50 years based on worst case component wear out mechanisms not based on wear out of process wetted materials Report any safety related product information a...

Страница 6: ...itzerland 41 0 41 768 6111 41 0 41 768 6300 RFQ RMD RCC Emerson com Asia Pacific Regional Office Emerson Automation Solutions 1 Pandan Crescent Singapore 128461 65 6777 8211 65 6777 0947 Enquiries AP Emerson com Middle East and Africa Regional Office Emerson Automation Solutions Emerson FZE P O Box 17033 Jebel Ali Free Zone South 2 Dubai United Arab Emirates 971 4 8118100 971 4 8865465 RFQ RMTMEA ...

Отзывы: