100
Reference Manual
00809-0100-4102, Rev AA
Appendix A: Reference Data
June 2012
Specifications and Reference Data
Conduit Electrical Connector
Standard
Standard
GE
M12, 4-pin, Male Connector (eurofast
®
)
★
GM
A size Mini, 4-pin, Male Connector (minifast
®
)
★
Hardware Adjustments
Standard
Standard
J1
(8)(9)
Local Zero Adjustment Only
★
No Local Zero or Span Adjustment
★
DZ
Digital Zero Trim
★
Transient Protection
Standard
Standard
T1
(10)
Transient Protection Terminal Block
★
Software Configuration
Standard
Standard
C1
Custom Software Configuration
(
Completed CDS 00806-0100-4001 required with order)
★
Low Power Output
Standard
Standard
C2
0.8–3.2 V dc Output with Digital Signal Based on HART Protocol (Available with Output code M only)
★
Alarm Limit
Standard
Standard
NAMUR alarm and saturation levels, high alarm
★
CN
(11)
NAMUR alarm and saturation levels, low alarm
★
Conduit Plug
Standard
Standard
DO
316 SST Conduit Plug
★
Ground Screw
Standard
Standard
V5
(12)
External Ground Screw Assembly
★
Lower Housing Flushing Connection Options
Ring Material
Number
Size (NPT)
Standard
Standard
F1
316 SST
1
1
/
4
-18 NPT
★
F2
316 SST
2
1
/
4
-18 NPT
★
F3
Alloy C-276
1
1
/
4
-18 NPT
★
F4
Alloy C-276
2
1
/
4
-18 NPT
★
F7
316 SST
1
1
/
2
-14 NPT
★
F8
316 SST
2
1
/
2
-14 NPT
★
F9
Alloy C-276
1
1
/
2
-14 NPT
★
F0
Alloy C-276
2
1
/
2
-14 NPT
★
Typical Model Number: 2051L
2
A
A0
D
21
A
A
F1
(1) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(2) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(3) Only valid with F
OUNDATION
fieldbus Output Code F.
Table A-7. Rosemount 2051L Liquid Level Transmitter Ordering Information
★
The Standard offering represents the most common options. The starred options (
★
) should be selected for best delivery.
__
The Expanded offering is subject to additional delivery lead time.
Содержание Rosemount 2051 Wireless Series
Страница 2: ......
Страница 12: ...4 Reference Manual 00809 0100 4102 Rev AA Section 1 Introduction June 2012 Introduction ...
Страница 32: ...24 Reference Manual 00809 0100 4102 Rev AA Section 2 Configuration June 2012 Configuration ...
Страница 105: ...118 Reference Manual 00809 0100 4102 Rev AA Appendix A Reference Data June 2012 Specifications and Reference Data ...
Страница 109: ...122 Reference Manual 00809 0100 4102 Rev AA Appendix B Product Certifications June 2012 Product Certifications ...
Страница 110: ......
Страница 113: ......
Страница 117: ...iv Reference Manual 00809 0100 4100 Rev AA Title Page June 2012 ...
Страница 123: ...x Reference Manual 00809 0100 4100 Rev AA Table of Contents June 2012 Table of Contents ...
Страница 167: ...44 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Страница 168: ...45 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Страница 169: ...46 Reference Manual 00809 0100 4100 Rev AA Section 3 Installation June 2012 Installation ...
Страница 248: ...146 Reference Manual 00809 0100 4100 Rev AA Appendix B Product Certifications June 2012 Product Certifications ...
Страница 249: ......