General Description

The XJ200 wireless communication modules are radio communication systems for con-

trolling and supervising units. The XJ200 consists of the 

XJ200

 radio module 

P/N 318-5050

 

and its power supply 

PW-200J

 

P/N 318-5051

.

The XJ200 can cover a variety of functions within the monitoring network:

Master:

 when it is connected to the X-WEB or E2 monitoring system.

Slave/Repeater:

 when it is connected to the subnets of devices equipped with RS485.

Repeater:

 when it is assigned the function as a simple bridge towards other subnets 

that cannot be reached directly by the master.

The XJ200 modules enable 2-way communication between Dixell devices/modules 

equipped with an RS485 output that are appropriately connected to each other and the X-

WEB or E2 unit, thereby replacing the connection via an RS485 cable.

Up to 15 devices can be connected to the same XJ200 (communication between the module 

and the devices is via RS485), thereby covering several workstations with the same commu-

nication module. Up to 30 XJ200 modules can be connected to one (1) master XJ200.

The maximum distance possible between the XJ200 modules in an open space (with no 

obstacles) is 200 meters (656 feet approx.). This distance can be remarkably reduced in the 

presence of interference such as radio emitters, generators of electrical or magnetic fields or 

solid objects that can affect the proper communication between the XJ200 modules.

The range of serial addresses allowed on the instruments connected to the XJ200 modules is 

from 1 to 244.

Note that in order to work with the XJ200 modules, the instruments must be equipped with 

an RS485 serial port and use 

MODBUS-RTU

 communication protocol.

Содержание PW-200J

Страница 1: ...master The XJ200 modules enable 2 way communication between Dixell devices modules equipped with an RS485 output that are appropriately connected to each other and the X WEB or E2 unit thereby replacing the connection via an RS485 cable Up to 15 devices can be connected to the same XJ200 communication between the module and the devices is via RS485 thereby covering several workstations with the sa...

Страница 2: ...his bulletin forms an integral part of the product and must be kept near the device for quick and easy reference The device must not be used for purposes other than those described below and particularly it cannot be used as a safety device Verify the limits of application before proceeding SAFETY PRECAUTIONS Verify that the connections comply with the instructions in this manual before connecting...

Страница 3: ...e latest technical documentation and updates technical bulletin Installation and Assembly Package Contents Each XJ200 package contains the following components 1 XJ200 radio device 2 Two self tapping screws 3 9x6 5T to mount the XJ200 to the fixing bracket 3 Wall fixing bracket 4 Instruction manual XJ200 Required Tools for Mounting Mounting Directly Parts required for assembly not supplied Figure ...

Страница 4: ...a guide to make the two holes B at the distance indicated in Figure 4 2 Insert the dowels and mount the screws with a maximum distance of 8 mm from the head to the wall 3 Fix the XJ200 to the head of the screws by rotating the con tainer appropriately Fixing with the Use of Bracket A suitable fastening bracket is included in every package to be used to shelf mounting pipe mount fitting with approp...

Страница 5: ...cal position Recommendations for Proper Installations If possible place the module high up in order to guarantee enhanced data transmission or reception If possible avoid intermediate obstacles such as barriers walls floors and counters between the modules If necessary pass through the obstacle using the cable and install the module on the opposite side in order to have it in direct view with the ...

Страница 6: ...s between 0 C and 60 C 32 F to 140 F Avoid places subject to heavy vibrations corrosive gas excessive filth or humidity Connections Each module is supplied complete with a 1 5 meter 4 9 feet approx cable to connect the serial com munication line and the power line The XJ200 is powered by 5V supplied by the PW 200J power supply The PW 200J requires 24VAC supply voltage input X WEB XJ200 Master Conn...

Страница 7: ...for the latest technical documentation and updates technical bulletin 2 Close the jumper found inside the XJ200 by inserting the micro switch as shown in the picture below 3 Close the cover of the XJ200 once again 4 Connect the XJ200 PW200J and the X WEB as shown in the connection diagram below NOTE When using the XJ200 with an XR XM or XEV controller the XJ200 external power supply must be used F...

Страница 8: ...1 Connect the GREEN wire of the XJ200 to the RS485 terminal of the X WEB 2 Connect the PINK wire of the XJ200 to the RS485 terminal of the X WEB 3 Power the X WEB and the PW200J once again XJ200 Connection and Devices Equipped with a Serial Output XJ200 and PW 200J Connection 1 Connect the white 5 pin connector to the 5V supply 5 pin connector of the PW 200J 2 Connect the other devices to the RS48...

Страница 9: ...wering the XJ200 Example Ranges Prime CX Wing Basic New XC400C and XC600C XJ200 and PW 200J Connection 1 Connect the GREEN wire to the RS485 terminal of the PW 200J 2 Connect the PINK wire to the RS485 terminal of the PW 200J 3 Connect the white connector to the 5V supply connector of the PW 200J Controller Connection with TTL and PW 200J 1 Connect the other devices to the RS485 serial line in com...

Страница 10: ...r Connection In the new installation you need to find a location in the store that has a direct line of sight with at least one or two wireless modules slave modules on the sales floor If the system performs up to four hops those in the indirect view can find their way to the master wireless module location to them From the designated position run a communication cable three conductors and wiring ...

Страница 11: ... may be photocopied for personal use Visit our website at http www emersonclimate com for the latest technical documentation and updates technical bulletin To turn a wireless module into a master module take off the cover and move the jumper over both pins otherwise the module remains a slave Figure 13 XJ200 Wireless with PW 200J Power Supply Figure 14 Jumper Positions ...

Страница 12: ...ical bulletin Connect the module s MODBUS wires to the E2 MODBUS network The MODBUS wires have reversed polarities The device can t be used with the E2 right away You may need to config ure the device first and connect it to the E2 NOTE The wiring polarity between the XJ200 and E2 is reversed Figure 15 Dixell MODBUS Networking E2 Property Location E2 Property New Value Menu 7 3 1 C7 MODBUSOffLnDly...

Страница 13: ...ersonal use Visit our website at http www emersonclimate com for the latest technical documentation and updates technical bulletin Note that the XJ200 requires E2 version 3 03F01 4 03F01 and higher The slave wireless modules on each case needs to be mounted upright with enough clear ance as possible see Figure 17 Figure 16 E2 MODBUS Delay Settings Figure 17 Slave Wireless Module Case Mounting ...

Страница 14: ...on 3 When the network is ready to operate start the acquisition procedure on the E2 The slaves and master modules will start to communicate when the E2 requires information to the MODBUS modules and starts coming online Removing a Node from the Wireless Network The master module can recognize if a node is removed from the network If a node is removed the master module will act as follows 1 The mas...

Страница 15: ... the yellow LED remains on reposition the slave module to improve line of sight with the master All devices appear on supervisory controller but status is off line Master is not communicating with Slave modules Ensure that you have followed the installation steps in the proper order A good communication path needs to be established between the master and slaves beforeconnectingthesupervisorycontro...

Страница 16: ...n the YELLOW RS485 LED is on in this case try installing the XJ200 in a better position or connect another XJ200 between the Master and the XJ200 being tested The Yellow RS485 LED remains on A good communication path has NOT been established between the master and slave module Ensure that the master and slave module have both been powered up Press the Test button on the front of the XJ200 slave mo...

Страница 17: ...ic Co 2013 Emerson Climate Technologies Retail Solutions Inc All rights reserved technical bulletin Technical Data The XJ200 0000 is compliant with the following standards ETSI EN 300 220 2 V2 1 2 2007 06 ETSI EN 301 489 3 V1 4 1 2002 08 CEI EN 60950 1 2007 02 It therefore meets the essential requirements of the following Directives Radio and telecommunications terminal equipment 99 5 EC Electroma...

Отзывы: