Thermal Validation
MVME6100 Single Board Computer Installation and Use (6806800D58E
)
110
B.3
Component Temperature Measurement
The following sections outline general temperature measurement methods. For the specific
types of measurements required for thermal evaluation of this board, see
Table B-1
.
B.3.1
Preparation
We recommend 40 AWG (American wire gauge) thermocouples for all thermal measurements.
Larger gauge thermocouples can wick heat away from the components and disturb air flowing
past the board.
Figure B-2
Thermally Significant Components–Secondary Side