Wiring
Figure 3-17: 9-wire cable to core processor
3. Ground the cable.
4. Ensure the integrity of the gaskets, grease all O-rings, then close the junction box
housing and core processor end-cap, and tighten all screws.
3.4
Connect the power supply wiring
Cable type
Procedure
Jacketed cable
Ground the shield drain wires (the black wire) only on the core
processor end, by connecting it to the ground screw inside the
lower conduit ring. Do not ground to the core processor’s
mounting screw. Do not ground the cable at the sensor junction
box.
Shielded or armored cable
Ground the shield drain wires (the black wire) only on the core
processor end, by connecting it to the ground screw inside the
lower conduit ring. Do not ground to the core processor’s
mounting screw. Do not ground the cable at the sensor junction
box.
Ground the cable braid on both ends, by terminating it inside the
cable glands.
CAUTION!
Make sure that the wires are not caught or pinched when you close the housing to reduce the risk of
measurement error or meter failure.
CAUTION!
• Do not install power supply wiring in the same cable tray or conduit as the input/output
wiring to avoid device failure or measurement error.
• Shut off the power supply before installing the applications platform.
• Make sure the power supply voltage matches the voltage that is indicated on the power
supply wiring terminals. See
Figure 3-18
.
Brown
Red
Green
White
Blue
Gray
Orange
Violet
Yellow
Black
(Drains from all
wire sets)
Plug and
socket
Mounting screw
Blue
Gray
Orange
Red
Green
White
Brown
Violet
Yellow
Ground screw
Black
9-wire cable from sensor
Core processor