Installation Manual
15
Wiring
Refer to the label attached to the terminal block. See
Figure 3-5
and
Figure 3-2
.
•
Use 24 to 16 AWG (0,25 to 1,5 mm
2
) twisted-pair shielded wire
•
Ground the shields at a single point only
The I/O terminal block ground is available for continuation of user cable shielding to I/
O cable shielding. The cable connector does not connect the I/O cable shielding to the
chassis ground.
Figure 3-4: Terminal block installation steps for I/O wiring on a DIN rail
Figure 3-5: Input/output wiring terminal label for I/O cables
DIN rail type TS 15
DIN rail type TS 32
DIN rail type TS 35 x 7,5
3 3/64
(77)
9
(229)
Label
3 17/32
(90)
Cable for input/output wiring
Connector
I/O terminal block
DIN rail type TS 35 x 15
2 37/
64
(66)
2 31/64
(63)
2 19/64
(59)
2 1/4
(57)
2 15/64
(57)
inches
(mm)
I/O terminal block