Configuration and Use Manual
27
Flowmeter Startup
Req
u
ir
ed
Con
fig
uration
O
pt
ion
a
l Co
nfi
g
u
ratio
n
Using the
T
ransmitter
Flo
w
me
te
r Sta
rtup
Figure 5-3
ProLink II – Loop test procedure
Figure 5-4
Communicator – Loop test procedure
Fix Milliamp 1/2
Fix Discrete Output
Read Discrete Input
Enter mA value
ON
or
OFF
Read output at
receiving device
Verify state at
receiving device
Toggle remote input
device
Verify state
at transmitter
Correct?
Correct?
Correct?
Check output wiring
Troubleshoot receiving device
Loop test successful
Check input wiring
Troubleshoot input device
Yes
No
Yes
No
Fix Freq Out
Read output at
receiving device
Correct?
Enter Hz value
Fix mA
Fix Frequency
Unfix
ProLink Menu >
Test
1 Fix Analog Out 1/2
3 Fix Discrete Out 1
ON
or
OFF
Read output at
receiving device
Verify state at
receiving device
Correct?
Correct?
Loop test successful
END
to unfix
Check output wiring
Troubleshoot receiving device
Yes
No
2 Fix Frequency Out
Read output at
receiving device
Correct?
4 mA
20 mA
Other
10 kHz
Other
On-Line Menu >
3 Diag/Service >
2 Loop test
Содержание Micro-Motion 2400S
Страница 8: ...vi Micro Motion Model 2400S Transmitters with Analog Outputs ...
Страница 20: ...12 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Страница 30: ...22 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Страница 42: ...34 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Страница 66: ...58 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Страница 76: ...68 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Страница 138: ...130 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Страница 190: ...182 Micro Motion Model 2400S Transmitters with Analog Outputs ...
Страница 197: ......