background image

9

Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not start.

1. Fuse or circuit breaker blown.

1. Check main and branch circuit fuses or circuit breakers.

2. Loose power line connections to the fan, or loose 

2. Check line power connections to fan and switch wire

switch wire connections in the switch housing.

connections in the switch housing.

WARNING: 

Make sure main power is turned off.

3. Reversing switch in neutral position.

3. Make sure reversing switch position is all the way to one side.

2. Fan sounds noisy.

1. Blades not attached to fan.

1. Attach blades to fan before operating.

2. Screws securing fan blade flanges to motor 

2. Check to make sure the screws which attach the fan flanges to the 

are loose. 

motor are tight. 

3. Wire connectors inside switch housing rattling.

3. Check to make sure wire connectors in switch housing are not

rattling against each other or against the interior wall of the switch
housing.

WARNING: 

Make sure main power is turned off.

4. Motor noise caused by solid-state variable

4. Some fan motors are sensitive to signals from Solid-State variable

speed control.

speed controls. If Solid-State Control is used and motor noise
results choose an alternative control method.

5. Screws holding blades to flanges are loose.

5. Tighten screws securely.

3. Fan wobbles

1. Setscrew in motor coupling is not tightened 

1. Raise coupling cover and tighten setscrew securely.

excessively.

securely.

2. Setscrew in the hanger ball/downrod assembly is 

2. Tighten the setscrew in the hanger ball/downrod assembly.

loose.

3. Screws securing fan blade flanges to motor are loose.

3. Check to be sure screws which attach the fan blade flanges to the 

motor are tight.

4. Fan blade flanges not seated properly.

4. Check to be sure the fan blade flanges seat firmly and uniformly to

the surface of the motor. If flanges are seated incorrectly, loosen
the flange screws and retighten according to the procedure in the 
section on "How to Put Your Ceiling Fan Together".

5. Hanger bracket and/or ceiling outlet box is not    

5. Tighten the hanger bracket screws to the outlet box, and/or secure

securely fastened

outlet box. 

6. Fan blades out of balance.

6. Interchanging an adjacent (side-by-side) blade pair can redistribute

the weight and result in smoother operation.

WARNING: 

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER

BEFORE TROUBLE SHOOTING YOUR FAN.

!

!

!

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

Maintenance

Accessories

1. Ceiling Fan Light Kits (see store or catalog).
2. Ceiling Fan/Light Controls (see store or catalog).
3. Downrod Extension Kits (see store or catalog).

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

WARNING

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal
injury or property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

WARNING

!

WARNING

!

Содержание MARIOL PORTICO CF690CK00

Страница 1: ...duct to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Cover...

Страница 2: ...Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blad...

Страница 3: ...om the loose parts bag in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan motor assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages o...

Страница 4: ... cover and the coupling cover are both oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten t...

Страница 5: ...ening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again 11 Remove and retain one of the three serrated head screws from the adaptor plate Figure 6 Loosen the other two serrated head screws three or ...

Страница 6: ... bracket WARNING AT LEAST 7 CEILING FLOOR Figure 10 The fan must be hung with at least 7 of clearance from floor to blades Figure 10 WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING 1 Securely attach the hanger bracket to t...

Страница 7: ...ible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is ground ed contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson E...

Страница 8: ... proper installation and use of the ceil ing fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal air flow Consult your Emerson Ret...

Страница 9: ...tach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten ...

Страница 10: ...R REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 6 4 9 8 5 7 11 10 19 18 13 15 16 12 17 1 2 3 20 14 ...

Страница 11: ... Knob 2 10 Pin Clevis 11 Clip Hairpin 15 Wood Pendant 16 Coupling 17 Screw Blade M5 x 6 Washer Head 16 20 Screw Flange M6 x 14 with Lockwasher 1 6 Ceiling Canopy 761504 19 761504 20 9 Coupling Cover 762463 2 762463 16 12 Bracket Switch Housing Assembly with Mounting Screws and 763237 763237 1 Rubber Cover 13 Switch Housing Assembly 763241 763241 1 14 Wiring Harness 762993 2 762993 2 18 Blade set o...

Страница 12: ...Part No F40BP73310000 Printed in China 10 06 Form No BP7331 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 ...

Отзывы: