How to Wire

Your Ceiling Fan

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1. Connect the green grounding lead from the hanger

ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire con-
nectors supplied. (Figure 13.)

NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner’s Manual
for wiring.

2. Securely connect the fan motor white wire to the

supply white (neutral) wire using wire connector
supplied (Figure 13). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied (Figure
13). After connections have been made, turn leads
upward and carefully push leads into the outlet
box, with the white and green leads on one side of
the outlet box and the black and blue leads on the
other side of the outlet box.

SUPPLY
GROUND
WIRE

LISTED
WIRE
CONNECTOR (3)

GREEN WIRE
(GROUND) FROM
HANGER BRACKET

GREEN WIRE
(GROUND) FROM
HANGER BALL

WHITE SUPPLY
(NEUTRAL)

WHITE FAN
WIRE

BLACK SUPPLY (HOT)

BLACK AND BLUE
FAN WIRES

THREADED 
STUD (2)

NOTE: CEILING COVER
OMITTED FOR CLARITY.

Figure 13

3. Screw the two threaded studs (supplied) into the

tapped holes in the hanger bracket (Figure 13).

4. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 14).

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.

WARNING

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or acces-
sories not designated for use with this product by
Emerson Electric Co. could result in personal injury
or property damage.

WARNING

!

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

5. Secure the ceiling cover in place by sliding

lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 14.)
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod. Your fan
is now wired to be turned on and off from the fan
switch.

6. Cut the 3-speed switch pull chain to a desired

length (optional). Connect the wood pendant
(supplied) to the 3-speed switch pull chain by
sliding the wooden pendant (small hole first) onto
the pull chain. Attach the chain coupler to the end
of the chain and allow the wooden pendant to fall
down over the coupling.

CEILING COVER

THREADED STUD

KNURLED KNOB

LOCKWASHERS (2)

Figure 14

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box and
not pinched between the ceiling cover and the ceiling.

WARNING

!

Содержание MARIOL PORTICO CF690CK00

Страница 1: ...duct to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Cover...

Страница 2: ...Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blad...

Страница 3: ...om the loose parts bag in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan motor assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages o...

Страница 4: ... cover and the coupling cover are both oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten t...

Страница 5: ...ening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again 11 Remove and retain one of the three serrated head screws from the adaptor plate Figure 6 Loosen the other two serrated head screws three or ...

Страница 6: ... bracket WARNING AT LEAST 7 CEILING FLOOR Figure 10 The fan must be hung with at least 7 of clearance from floor to blades Figure 10 WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING 1 Securely attach the hanger bracket to t...

Страница 7: ...ible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is ground ed contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson E...

Страница 8: ... proper installation and use of the ceil ing fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal air flow Consult your Emerson Ret...

Страница 9: ...tach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten ...

Страница 10: ...R REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 6 4 9 8 5 7 11 10 19 18 13 15 16 12 17 1 2 3 20 14 ...

Страница 11: ... Knob 2 10 Pin Clevis 11 Clip Hairpin 15 Wood Pendant 16 Coupling 17 Screw Blade M5 x 6 Washer Head 16 20 Screw Flange M6 x 14 with Lockwasher 1 6 Ceiling Canopy 761504 19 761504 20 9 Coupling Cover 762463 2 762463 16 12 Bracket Switch Housing Assembly with Mounting Screws and 763237 763237 1 Rubber Cover 13 Switch Housing Assembly 763241 763241 1 14 Wiring Harness 762993 2 762993 2 18 Blade set o...

Страница 12: ...Part No F40BP73310000 Printed in China 10 06 Form No BP7331 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 ...

Отзывы: