Introduction
3
Liebert
®
IntelliSlot
™
Unity
™
Card User Manual
1.0 Introduction
This Liebert IntelliSlot Unity platform delivers enhanced communication and control of AC Power, Power
Distribution and Thermal Management products. The platform communicates with Emerson Network
Power
®
software tools and services, including Trellis
®
, LIFE
™
Services, Liebert SiteScan Web
™
and Liebert
Nform
®
.
The platform includes the Liebert IntelliSlot Unity-DP
™
and Liebert IntelliSlot Unity LIFE
™
cards.
Each card employs the Emerson Protocol to monitor and manage a wide range of operating parameters,
alarms and notifications about power, distribution and cooling equipment. The cards also communicate
with Building Management Systems and Network Management Systems. Liebert IntelliSlot Unity cards
support monitoring of sensors to improve system reliability and efficiency.
Figure 1-1 Liebert IntelliSlot Unity-DP card features
1.1 Protocols
Each card supports the Emerson Protocol, Remote Service Delivery Protocol and HTTP Web by default.
The Liebert IntelliSlot Unity-DP supports selecting two third-party protocols; the Liebert IntelliSlot Unity
LIFE card supports the default protocols only (Emerson Protocol, Remote Service Delivery Protocol and
HTTP Web).
Available protocols are
• BACnet IP—BACnet over Internet Protocol
• BACnet MSTP—BACnet Master-Slave/Token-Passing (MSTP) communications protocol over a RS-
485 serial network (also known as BACnet MSTP RS-485)
• Modbus RTU—Modbus Remote Terminal Unit (RTU) communication protocol over a RS-485 serial
network (also known as Modbus RTU RS-485)
• Modbus TCP—Modbus Transmission Control Protocol over Internet Protocol (also known as Modbus
TCP/IP)
• SNMP
• YDN23 - YD-T-1363 specification protocol (also known as YD/T 1363)
Activity
Link
485
IS-UNITY-DP
Liebert Sensor Network
RJ-45-Ethernet—HTTP; Modbus TCP;
BACnet IP; SNMPv1, v2c, v3;
Emerson Protocol
Reset
Button
(Reboot or
reset to
factory
defaults)
BACnet MSTP
Modbus RTU
YDN23
Micro-USB AB
(future release)
Содержание Liebert Intellislot Unity Card
Страница 1: ...Liebert IntelliSlot Unity Card User Manual Web SNMP Modbus BACnet YDN23 ...
Страница 2: ......
Страница 6: ...Liebert IntelliSlot Unity Card User Manual iv Page intentionally left blank ...
Страница 8: ...Liebert IntelliSlot Unity Card User Manual vi Page intentionally left blank ...
Страница 10: ...Liebert IntelliSlot Unity Card User Manual viii Page intentionally left blank ...
Страница 12: ...Important Safety Instructions Liebert IntelliSlot Unity Card User Manual 2 Page intentionally left blank ...
Страница 16: ...Introduction Liebert IntelliSlot Unity Card User Manual 6 Page intentionally left blank ...
Страница 38: ...Enable Communication Protocols Liebert IntelliSlot Unity Card User Manual 28 Page intentionally left blank ...
Страница 88: ...Firmware Updates Liebert IntelliSlot Unity Card User Manual 78 Page intentionally left blank ...
Страница 91: ......