9
INS
TALL
A
TION
Installation
Wiring Guide for Equipment Accessories
HM
HM
2
Non-Powered
Humidifier
Transformer
R
C
HM DRY
RH
HM
2
Fig.
3
- Humidifier. HM terminal provides system
24V
on call for humidification
Fig.
4
- Powered Humidifier. With HM DRY switch in HM
2
position, HM
and HM
2
provide normally open dry contact for low voltage (
24
V) powered
humidifier connection.
HM
HM
2
Non-Powered
Humidifier
HM DRY
RH
HM
2
Fig.
5
- Powered Dehumidifier. With DHM DRY switch in DHM
2
position,
DHM and DHM
2
provide normally open dry contact for low voltage (
24
V)
whole house powered dehumidifier connection.
DHM
DHM
2
Powered
Dehumidifier
DHM DRY
RH
DHM
2
Содержание Inspire 1HDEZ-1521
Страница 31: ......