11
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: HF948 & HF956
4.4
This fan is equipped with the required retention cable.
This cable must be affixed to the building structure and
securely clamped in such a manner to support the weight
of the fan in the event the mounting hook or other parts fail.
After wrapping cable around or to a structural member that
will support 50 pounds, secure cable with supplied cable
clamps as illustrated in Figure 14.
NOTE: Leave approximately 3" but no more than 5" of
slack on this safety cable to allow for possible fan
movement. Do not exceed more than 5" total slack.
CAUTION: It is important to note the proper
installation position of the cable clamps as illustrated
in Figure 14. To obtain maximum holding power,
install U-bolt section of clip on dead or short end of
cable and saddle on long end of cable. Improper
installation reduces the efficiency of the connection by
as much as 40 percent.
TO SUPPORT
STRUCTURE
TO
FAN
CABLE
CLAMPS (2)
RETENTION
CABLE
Figure 14
4. How to Hang Your Ceiling Fan
(Continued)
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
5.1
Connect the green grounding wire from the fan motor to
the green grounding wire from the supply source (this may
be a bare wire or wire with green colored insulation).
Securely connect wires with a wire connector (supplied)
(Figure 15).
CAUTION: Use larger U.L. listed wire connectors if
supply source wires are larger than #12 AWG.
5. How to Wire Your Ceiling Fan
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
This product is designed to use only those parts supplied
with this product and/or any accessories designated
specifically for use with this product by Emerson Electric
Co. Substitution of parts or accessories not designated
for use with this product by Emerson Electric Co. could
result in personal injury or property damage.
WARNING
!
SUPPLY GROUND
WIRE
GREEN WIRE
(GROUND)
FROM FAN
WIRE CONNECTOR
Figure 15
Содержание HF948BS02
Страница 20: ...10 Repair Parts 1 2 4 5 6 11 12 18 14 13 17 15 7 16 8 3 9 20 U L Model No HF948 HF956 ...
Страница 22: ...Notes 22 U L Model No HF948 HF956 ...
Страница 44: ...1 2 4 5 6 11 12 18 14 13 17 15 7 16 8 3 9 44 No de modelo U L HF948 y HF956 10 Piezas de repuesto ...
Страница 46: ...46 No de modelo U L HF948 y HF956 Notas ...
Страница 68: ...1 2 4 5 6 11 12 18 14 13 17 15 7 16 8 3 9 68 Modèle U L N HF948 HF956 10 Pièces de rechange ...
Страница 70: ...70 Modèle U L N HF948 HF956 Remarques ...