6
ETL Model No.: CF840
3. Ceiling Fan Assembly
(Continued)
REINSTALL & TIGHTEN
ONE #6-32 x 1/4" TRUSS
HEAD SCREW
WITH LOCKWASHER
RETIGTEN TWO #6-32 x 1/4"
TRUSS HEAD SCREWS
WITH LOCKWASHERS
LOWER HOUSING
ASSEMBLY
Figure 4
3.4
Place the 2-pin Motor Assembly Wires and Connector
through the Lower Housing Assembly Center Hole
(Figure 4).
Position the Lower Housing Assembly Key Hole Slots
onto the Two Loosened Screw Heads.
Rotate the Lower Housing Assembly Clockwise to
engage the Two Screws.
NOTE: Verify that the washers are not trapped
between the Lower Housing Assembly and the
Motor Assembly Hub.
Reinstall and Tighten the previously removed
#6-32 x 1/4” Truss Head Screw with Lockwasher
(Figure 4).
Retighten all Three #6-32 x 1/4” Truss Head Screws
with Lockwashers to securely attach the Lower
Housing Assembly to the Motor Assembly Hub
(Figure 4).
A spare #6-32 x 1/4” Truss Head Screw with
Lockwasher is supplied in the parts bag, if needed.
REMOVE ONE #6-32 x 1/4"
TRUSS HEAD SCREW
WITH LOCKWASHER
MOTOR ASSEMBLY
HUB
LOOSEN TWO #6-32 x 1/4"
TRUSS HEAD SCREWS
WITH LOCKWASHERS
3.3
Remove and Retain One of the Three #6-32 x 1/4”
Truss Head Screw with Lockwasher from the Motor
Assembly Hub (Figure 3).
Loosen the remaining Two #6-32 x 1/4” Truss Head
Screws with Lockwashers (Figure 3).