Instruction Manual
D103416X012
SS-84PSV4 Valve
September 2022
5
NOTICE
Care must be taken when lifting the valve/actuator assembly to ensure the accessories and tubing are not damaged in the
process. Accessories and tubing may need to be removed prior to lifting to prevent damage and properly reinstalled before
use. Protect valve flange faces, butt weld ends, and other connection surfaces from damage during lifting.
The quantity of eyebolts for lifting purpose is the minimum recommendation. More eyebolts can be used per customer
experience. When tightening the eyebolts and nuts, do not exceed the torque that is specified in the following section, to
avoid damage on the diaphragm.
Figure 2. Lifting Guidelines
VALVE/ACTUATOR ASSEMBLY
VALVE ONLY
ACTUATOR ONLY
W100061
W100062
W100063
Lifting Valve/Actuator Assembly
To lift the assembly, insert 3/4-10 thread size hoist rings into the two tapped holes on the top of the valve body. These
two tapped holes will carry most of the weight, but the assembly must be balanced using one or more straps on the
1052PSV casing as shown in figure 2. The ends of the strap(s) will be positioned underneath two L-shaped flanges or
through eyebolts. Figure 2 shows L-shaped flanges attached to the casings. An alternative casing lift method is to use
3/8 inch eyebolts positioned 180 degrees apart. Use protective pads between the strap(s) and the casing to help
prevent damage to the painted surface. Torque the 3/8-24 cap screws or eyebolts and nuts to 20 lbf•-ft. The assembly
can now be lifted using a hoist capable of leveling these lifting points.