Instruction Manual
D104239X012
Multiport Flow Selector
January 2019
36
Factory Settings - Port Calibration
Port Calibrations are made by Factory Authorized
Technicians through the Factory Menu only accessible
by Factory Authorized Technicians with DCMLink
License authorization.
Select Port Calibration from the Factory Menu Options.
See figure 19.
For precise MPFS port alignment, the factory calibrates
each actuator to each of the ports of the mated MPFS.
These items are in the “.mpa” configuration file saved
by the Factory and can be loaded to or saved from a PC
during any service or CPU replacement.
The calibrated values are displayed on the Port
Calibration screen and may be compared to the
current position (Encoder Feedback) to determine
accuracy. When a new home port is selected by the
user, these calibration values are recalculated and
stored to EEPROM. See figure 20.
Figure 18.
Figure 19.
Figure 20.